Scheppach 5908403901 Translation From The Original Instruction Manual Download Page 15

The machine has protective insulation!

Caution!

The protection class is retained only if original insulating 

material is used during maintenance and the insulation dis-

tances are not changed.

Pull the power plug out before cleaning or maintenance!

   

Size: 20 (mm)     40 (mm)

Ø 25 mm

129 x 70

The concrete mixer can be operated only with fully closed 

protection device!

 

 

 

 

Wear protective clothes!

 

Do not put your hands into the moving drum!

Caution!

Risk of getting crushed at the sprocket

Installation help!

See: Installation, installing the upper section of the drum 

(Fig.6)

Correct use according to manufacturer´s instructions 

m

The machine corresponds to the applicable 

EC Machine Directive.

• 

The concrete mixer is intended exclusively 

for private use at home and in the garden.

• 

It should be operated only within the frame-

work of the technical data.

• 

The concrete mixer is meant exclusively for 

the production of concrete and mortar. 

• 

The applicable accident prevention rules 

and the other generally recognised techni-

cal safety regulations must be observed.

• 

The machine may be used, serviced or 

repaired only by persons who are familiar 

with it and are instructed about its risks. 

Arbitrary alterations in the machine will free 

the manufacturer from any liability for the 

resulting damage.

• 

The machine is to be used only with the 

manufacturer’s original accessories and  

original tools. 

• 

Any use that goes beyond this will be 

treated as improper use. The manufacturer 

will not be responsible for damage resulting 

from improper use; the risk will be borne 

solely by the user.

Caution! The Following Actions are Forbid

-

den:

Operation in atmosphere that is exposed to 

the risk of explosion

Use in the food products industry 

Mixing explosive, combustible and health-

endangering substances. 

Residual risks 

m

The machine is built on the basis of the 

latest technology and in accordance with the 

recognised technical safety rules. Never

-

theless, individual residual risks can occur 

while working.

• 

Risk of injury from rotating parts

• 

Risk from power where improper electrical 

connecting cables are used

• 

Further, indeterminate residual risks may 

remain even after taking all relevant pre-

ventive measures.

• 

Residual risks can be minimised if the sa-

fety instructions and conditions for proper 

use, as well as the operating instructions, 

are observed

Electrical connection 

m

The installed electric motor is connected in 

operation-ready condition. The connection 

corresponds to the common VDE and DIN 

provisions.

The customer-side mains connection, as well as 

the used extension cable, must correspond to 

these specifications.

Important Instructions

In case of overload, the motor is switched off 

automatically.

• 

The motor can be activated again after a 

cooling period (different times for different 

models).

Damaged Electrical Connecting Cables

Electrical connecting cables frequently experi-

ence insulation damage.

The causes are:

• 

Pressure points, if connecting cables are 

routed through windows or doors.

• 

Kinks, due to improper mounting or routing 

of the connecting cables.

• 

Cuts due to connecting cables being run 

over.

• 

Insulation damages due to tearing away 

from the wall socket.

• 

Cracks in insulation due to ageing. Such 

damaged electrical connecting cables 

should not be used, they can be fatal due to 

damaged insulation!

Check electrical connecting cables regularly 

for damage. Ensure that when checking the 

connecting cable, it does not hang from the 

power mains. Electrical connecting cables must 

correspond to the common VDE and DIN provi-

sions. Use only connecting cables that have the 

designation H 07 RN.

An imprint of the type designation on the con-

necting cable is mandatory.

AC Motor

AC motor 230 V/ 50 Hz, mains voltage 230 Volt 

/ 50 Hz.

Use of a residual current protection device (“FI“) 

is recommended for a 230V connection. If you 

use an extension cable, insert it directly into the 

FI.

15

D

GB

Summary of Contents for 5908403901

Page 1: ...nleitung GB Concrete mixer Translation from the original instruction manual FR B tonni re Traduction du manuel d origine I Betoniera Vertaling van originele handleiding SK Mie a ka bet nu Preklad orig...

Page 2: ...Translation from the original instruction manual 14 FR B tonni re Traduction du manuel d origine 18 I Betoniera Vertaling van originele handleiding 23 SK Mie a ka bet nu Preklad origin lneho n vodu 28...

Page 3: ...Fig 6 Fig 7 Fig 8 Fig 9 Fig 10 Fig 11 Art Nr 590 8403 901 5908403850 09 2012 D Betonmischer Original Anleitung GB Concrete mixer Translation from the original instruction manual FR B tonni re Traducti...

Page 4: ...4 Fig 3 Fig 4 2 M8 70 Fig 5 2 M8 70 Fig 6 Fig 7 2 M8 65 1 42 2 M8 20...

Page 5: ...Fig 8 Fig 9 Fig 10 F 2 M8 20 6 M8 16 2 M8 25 1 M10 65...

Page 6: ...Fig 11 4 M8...

Page 7: ...z cia Poloha pro vyprazd ov n Lager Position Storage position Position de rangement Memorizzazione della posizione Pam ov poz cia Poloha pro skladov n F r M rtel For mortar Pour le mortier Per malta p...

Page 8: ...WIRING DIAGRAM Fig 13...

Page 9: ...die nachstehenden grundlegenden Sicherheitsvorkehrungen befolgen um so das Risiko von Feuer elek trischem Schlag und Personenverletzungen zu reduzieren Bitte lesen Sie alle Anweisungen bevor sie mit...

Page 10: ...wenn die Sicherheitshinweise und die Bestim mungsgem e Verwendung sowie die Bedienungsanweisung beachtet werden Elektrischer Anschluss m Der installierte Elektromotor ist betriebsfertig angeschlossen...

Page 11: ...Betriebszyklus sind zu ber cksichtigen beispielsweise Zeiten in denen das Elektrowerkzeug abgeschaltet ist und solche in denen es zwar eingeschaltet ist aber ohne Belastung l uft Auspacken Betonmische...

Page 12: ...ellen 2 Beim Transport mit einem Fahrzeug Schrauben entfernen und F e einklappen 3 Mischer mit Spanngurt gegen Verschiebungen sichern 4 Betonmischer nicht mit dem Kran anheben Wartung Achtung Bei alle...

Page 13: ...genau befolgt Wenn die Maschine ausgedient hat geht man unter Beachtung aller angegebenen Unfallverh tungsnormen folgenderma en vor die Energiezufuhr unterbrechen elektrisch oder PTO alle Stromkabel...

Page 14: ...tools please comply with the basic safety related preven tive measures given below so as to minimize the risk of fire electric shock and physical injuries Please read all the instructions before star...

Page 15: ...t technology and in accordance with the recognised technical safety rules Never theless individual residual risks can occur while working Risk of injury from rotating parts Risk from power where impro...

Page 16: ...of ways to reduce vibration levels are wearing gloves when using the tool and limiting working hours In doing so all parts of the operating cycle must be taken into account for example times in which...

Page 17: ...g cables should not be used Cleaning Caution Switch off the machine wait for the drum to come to a standstill and pull out the power plug Clean the drum with water after each use of the concrete mixer...

Page 18: ...ques vous devriez suivre les mesures pr ventives de s curit fon damentales suivantes afin de r duire les risques d incendie de choc lectrique et de blessures Veuillez lire toutes les indications avant...

Page 19: ...ion Sont interdits Le fonctionnement dans des atmosph res explosibles L utilisation dans le secteur alimentaire Le m lange de substances explosives inflammables et nocives Risques r siduels m La machi...

Page 20: ...ons 1200mm x 710mm x 1400mm Poids 50 kg Information sur le bruit Les niveaux sonores de la machine en fonction nement sont les suivants LpA 7 2dB A K 3dB A LwA 93dB A K 3dB A Vibration 4 51m s2 K 1 5m...

Page 21: ...il une prise lectrique Position marche sur I bouton vert Position d arr t sur 0 bouton rouge R glage du tambour Fig 12 Pour ajuster le tambour vous devez pous ser en arri re la manivelle lat rale de s...

Page 22: ...au rebut normalement Pour la mise au rebut s adresser des entrepri ses sp cialis es ou un personnel qualifi con naissant les risques ventuels ayant lu et suivi la lettre les pr sentes notices d utili...

Page 23: ...o si utilizzano uten sili elettrici osservare le seguenti misure di sicurezza di base per ridurre il rischio di incendi scariche elettriche e lesioni perso nali Leggere tutte le istruzioni prima di in...

Page 24: ...secondo tecnologie all avanguardia e conformemente alle regole di tecnica di sicurezza ricono sciute Tuttavia durante il suo impiego si possono presentare rischi residui Pericolo di lesioni a causa d...

Page 25: ...es luci flash Se la tensione elettrica corrisponde a Zmax 0 27 un interferenza di questo tipo non dovrebbe veri ficarsi Se invece si verifica avvisare il rivendi tore Il valore dell emissione della v...

Page 26: ...buro in funzione Non sovraccaricare il tamburo Attenzione Pericolo di parti in movi mento Svuotamento Ruotare il tamburo verso il basso per svuotarlo Assicurarsi che sotto al tamburo ci sia un conteni...

Page 27: ...olosamente Al termine della vita utile della macchina procedere in questo modo osservando tutte le norme antinfortunistiche indicate interrompere l alimentazione energetica elettrica o PTO rimuovere t...

Page 28: ...nostn pokyny m Body t kaj ce sa bezpe nosti sme v tomto n vode ozna ili t mto symbolom m VAROVANIE Ke pou vate elektrick n stroje mali by ste dodr iava nasleduj ce z sadn bezpe nostn opatrenia aby sa...

Page 29: ...tatkov rizik je mo n minimalizova ak sa dodr iavaj bezpe nostn upozor nenia pou itie v s lade s ur en m ako aj n vod na obsluhu Elektrick pr pojka m Nain talovan elektromotor je pripojen a pripraven n...

Page 30: ...e a ku bet nu musia z kart nu vybera dve osoby Skontrolujte plnos obsahu V pr pade nedostatkov informujte predajcu Mont Pozor Mie a ka bet nu sa smie pou va a po kom pletnej mont i 1 Mont kolies obr 3...

Page 31: ...rave vozidlom odstr te skrutky a sklopte nohy 3 Mie a ku zaistite up nac m popruhom aby sa nepohybovala 4 Mie a ku bet nu nedv hajte eriavom dr ba Pozor Pri v etk ch pr cach alebo oprav ch mie a ky be...

Page 32: ...resne dodr iava dostupn n vody na pou vanie Ke stroj dosl i postupujte nas ledovne dodr iavaj c v etky uveden predpisy pre BOZP preru te pr vod energie elektrick alebo PTO odstr te elektrick k ble a o...

Page 33: ...t kaj bezpe nosti jsme v tomto n vodu ozna ili t mto symbolem m V STRAHA Pokud pou v te elektrick n stroje m li byste se dit n e uveden mi z kladn mi bezpe nostn mi opat en mi abyste zmen ili nebezpe...

Page 34: ...du s ur en m i n vod k obsluze P vod elekt iny m Instalovan elektromotor je p ipojen v provo zuschopn m stavu P pojka mus odpov dat p slu n m p edpis m VDE a DIN T mto p edpis m mus odpov dat s ov p p...

Page 35: ...i vyjm te za pomoci dvou osob z kartonu Zkontrolujte zda je obsah pln V p pad nedostatk informujte prodejce Mont Pozor M cha betonov sm si sm te pou vat a po kompletn mont i 1 Mont kol obr 3 K podstav...

Page 36: ...te nohy 3 M cha zajist te nap nac mi gumov mi p sy proti posunut 4 M cha betonov sm si nezdvihejte pomoc je bu dr ba Pozor P i jak koli pr ci nebo oprav ch m cha e beto nov sm si M cha betonov sm si v...

Page 37: ...a p esn je dodr uje Kdy stroj doslou postupujte n sleduj c m zp sobem a dbejte p itom v ech uveden ch norem pro prevenci raz P eru te p vod energie elektrick nebo PTO odstra te v echny elektrick kabe...

Page 38: ...38...

Page 39: ...raipsn LV apliecina du saska ar ES direkt vu atbilst bas un standarti du rakstu NL verklaart hierbij dat het volgende artikel voldoet aan de daarop betrekking hebbende EG richtlijnen en normen RUS PT...

Page 40: ......

Page 41: ...direktiv 2002 96 EF em bortskaffelse af elektriske og elektroniske produkter og g ldende national lovgivning skal brugt elv rktoj indsamles separat og bortskaffes p en m de der sk ner milj et mest mul...

Page 42: ...jd av material eller tillverkningsfel F r delar som vi inte sj lva tillverkar l mnar vi endast garanti i s m tto som vi sj lva f r garanti av v ra underleverant rer Kostnaderna f r monteringen av de n...

Reviews: