www.scheppach.com /
+(49)-08223-4002-99 /
+(49)-08223-4002-58
GB | 25
This product must be disposed of at a designated
collection point. This can occur, for example, by
handing it in at an authorised collecting point for the
recycling of waste electrical and electronic equip-
ment. Improper handling of waste equipment may
have negative consequences for the environment
and human health due to potentially hazardous sub-
stances that are often contained in electrical and
electronic equipment. By properly disposing of this
product, you are also contributing to the effective
use of natural resources. You can obtain information
on collection points for waste equipment from your
municipal administration, public waste disposal au-
thority, an authorised body for the disposal of waste
electrical and electronic equipment or your waste
disposal company.
11. Disposal and recycling
The equipment is supplied in packaging to prevent it
from being damaged in transit. The raw materials in
this packaging can be reused or recycled. The equip-
ment and its accessories are made of various types
of material, such as metal and plastic. Defective
components must be disposed of as special waste.
Ask your dealer or your local council.
Old devices must not be disposed of with house-
hold waste!
This symbol indicates that this product must
not be disposed of together with domestic
waste in compliance with the Directive
(2012/19/EU) pertaining to waste electrical and elec-
tronic equipment (WEEE).
12. Troubleshooting
Fault
Possible cause
Remedy
The compressor does
not start.
No supply voltage.
Check the supply voltage, the power plug and the
socket-outlet.
Insufficient supply voltage.
Make sure that the extension cable is not too long.
Use an extension cable with large enough wires.
Outside temperature is too low.
Never operate with an outside temperature of below
+5° C.
Motor is overheated.
Allow the motor to cool down. If necessary, remedy
the cause of the overheating.
The compressor starts
but there is no pres-
sure.
The non-return valve leaks.
Have a service center replace the non-return valve.
The seals are damaged.
Check the seals and have any damaged seals re-
placed by a service center.
The drain plug for condensation
water (9) leaks.
Tighten the screw by hand. Check the seal on the
screw and replace if necessary.
The compressor
starts, pressure is
shown on the pressure
gauge, but the tools
do not start.
The hose connections have a leak.
Check the compressed air hose and tools and replace
if necessary.
A quick-lock coupling has a leak.
Check the quick-lock coupling and replace if neces-
sary.
Insufficient pressure set on the pres
-
sure regulator (3).
Increase the set pressure with the pressure regulator.