• Kinks where the connection cable has been im-
properly fastened or routed.
• Places where the connection cables have been cut
due to being driven over.
• Insulation damage due to being ripped out of the
wall outlet.
• Cracks due to the insulation ageing.
Such damaged electrical connection cables must not
be used and are life-threatening due to the insula-
tion damage.
Check the electrical connection cables for damage
regularly. Make sure that the connection cable does
not hang on the power network during the inspection.
Electrical connection cables must comply with the
applicable VDE and DIN provisions. Only use con-
nection cables with the marking „H07RN“.
The printing of the type designation on the connec-
tion cable is mandatory.
For single-phase AC motors, we recommend a fuse
rating of 16A (C) or 16A (K) for machines with a high
starting current (starting from 3000 watts)!
Three-phase motor 400 V / 50 Hz
Mains voltage 400 V / 50 Hz
Mains voltage and extension cables must be 5-lead
(3P + N + SL (3/N/PE). Extension cables must have
a minimum cross-section of 1.5 mm². Mains fuse pro-
tection is 16 A maximum.
When connecting to the mains or relocating the ma-
chine, check the direction of rotation (swap polarity in
the wall socket if necessary). Turn pole inverter in the
machine socket.
12. Cleaning
Attention!
Pull out the power plug before carrying out any clean-
ing work on the equipment.
We recommend that you clean the equipment imme-
diately after you use it.
Clean the equipment regularly with a damp cloth and
some soft soap. Do not use cleaning agents or sol-
vents; these may be aggressive to the plastic parts in
the equipment. Ensure that no water can get into the
interior of the equipment.
13. Transport
Move the splitter to the transport position beforehand.
See item 9.3, proceed in reverse order.
•
Force jammed logs out by applying pressure in
the splitting direction or by raising the riving
knife. In this case, only push the handles up,
do not use the return bracket. Caution: Risk of
injury
Operating the log lifter (7)
General information about the log lifter:
• For safety reasons, the log lifter chain may only be
hung on the splitting blade with the last link.
• Ensure that nobody else is within the working envi-
ronment of the log lifter.
Operating the log lifter:
• Loosen the log lifter restraining hook so the lifting
tube can move freely.
• Move the splitting blade so far down that the log
lifter lifting tube lies on the ground.
• In this position, you can roll the log to be split onto
the lifting tube. (The log has to be between the two
fixing tips.)
• Push the return bracket down or the handles up
so the splitting blade moves up. (Caution! Do not
stand in the working environment of the log lifter!
Risk of injury!)
• Then remove the split wood and move the riving
knife and therefore the log lifter back down.
• Now you can roll a new log onto the log lifter.
Resetting the log lifter
This is used as a second guard arm when not using
the trunk lifter or when automatic return is enabled.
For this, the arm is moved up until it locks in position
in the hook.
Transport position of the log lifter:
• Using your hand, move the log lifter up until it locks
in position.
Comply with these notices to ensure quick and
safe work.
11. Electrical connection
The electrical motor installed is connected and ready
for operation. The connection complies with the ap-
plicable VDE and DIN provisions.
The customer‘s mains connection as well as the ex-
tension cable used must also comply with these reg-
ulations.
Damaged electrical connection cable
The insulation on electrical connection cables is of-
ten damaged.
This may have the following causes:
• Passage points, where connection cables are
passed through windows or doors.