Installation instructions for solar charge regulator LRM 1218
10
Date: 22.07.2015
822.0213 MA / EN
5.3 Connection to an EBL ... electroblock with 3--pin MNL con-
nection and adapter for starter battery
When using an electroblock which only has a 3--pin connection for a solar
charge regulator, an adapter for charging the starter battery can be retrofit-
ted. It is then possible to charge the leisure area and starter batteries simul-
taneously.
The following electroblocks (as of April 2008) can be used with the adapter:
F
EBL 99
F
EBL 100
F
EBL 264-9
F
EBL 240
F
EBL 269
An LT 320 operating and display panel, for the display of solar charge cur-
rents, can be used as an optional accessory.
For this application, the follow parts are required from those delivered:
Fig./Pos.
Qty
Name
1
1
LRM 1218 solar charge regulator
1/1 or 2
1
20A or 15A flat vehicle fuse (depending on EBL ...)
2/2
1
EBL ... connector cable (leisure area battery charge
current). Here the middle wire on the connector
must be detached and the red cable be pulled from
the insulating sleeve.
2/3
1
EBL ... connector cable (starter battery charge cur-
rents) is looped in between cable loom and EBL
--
2
Wire end sleeves (not included in delivery)