Fault
Remedy
Possible cause
Starter battery is not charged
No mains voltage
Switch on the automatic circuit
Starter battery is not charged
during 230V operation (battery
No mains voltage
Switch on the automatic circuit
breaker in the vehicle; check the
g
p
(
y
voltage permanently below
13 0 V)
;
mains voltage
13.0 V)
Too many consumers are swit-
ched on
Switch off any consumers not
required
Defective electroblock
Contact customer service
Leisure battery is not charged
d i
bil
i
(b
Defective alternator
Have the alternator checked
y
g
during mobile operation (battery
voltage below 13.0 V)
No voltage on D+ input
Have the fuse and cabling chek-
ked
D+ switch on electroblock is not
set correctly.
Set the switch according to the
D+ signal from the vehicle (12V
or active ground)
Defective electroblock
Contact customer service
The leisure battery is overchar-
ged during mobile operation
(battery voltage permanently
above 14,3/14,7 V)
Defective alternator
Have the alternator checked
The refrigerator does not work
during mobile operation
No power supply to the refrige-
rator
Have the fuse (20A of supply;
possibly 1A of the D+ signal)
and wiring checked
Defective electroblock
Contact customer service
Defective refrigerator
Have the refrigerator checked
Solar charging does not work
Solar charge regulator not plug-
Plug in solar charge regulator
Solar charging does not work
Solar charge regulator not plug
ged in
Plug in solar charge regulator
Defective fuse or cabling
Have the fuse and cabling chek-
ked
Solar charge regulator defective Have solar charge regulator
checked
12V supply in the leisure area
12V main switch for the leisure
12V main switch for the leisure
12V supply in the leisure area
does not work
12V main switch for the leisure
battery is switched off
12V main switch for the leisure
battery must be switched on
Not all plugs/fuses are plugged
Pug all plugs and fuses (correct
Not all plugs/fuses are plugged
into the electroblock
Pug all plugs and fuses (correct
ratings) into the electroblock
Defective fuse or cabling
Have the fuse and cabling chek-
Defective fuse or cabling
Have the fuse and cabling chek
ked
Defective electroblock
Contact customer service
The charging current is reduced automatically if the device becomes too hot due to exces-
sive ambient temperature or lack of ventilation. Always prevent the device from overheating
nevertheless.
CAUTION!
When the automatic shut-off of the battery monitor is activated (also see the operating in-
structions for the DT / LT ... operator and control panel) , fully charge the leisure battery.