Electroblock EBL 220-4 A / EBL 220-4 with OVP instruction manual
6
Issued: 21.06.2010
811.592 BA / EN
The following functions are protected by self-resetting fuses too:
F
Current measurement
F
Illumination control and switch panel
F
Main Switch
When faults expected in these functions, disconnect the electroblock com-
pletely from 12 V for approx. 1 min (best: disconnecting the battery poles).
Please contact our customer service address if you cannot eliminate the
fault using the following table.
If this is not possible, e.g. if you are abroad, you can have the Electroblock
repaired at a specialist workshop. In this case you must ensure that the
warranty is not invalidated by incorrect repairs being carried out and Schaudt
GmbH will not accept any liability for damage resulting from such repairs.
If a fault has been caused by a defective DT/LT ... control and switch panel it
is always possible to run emergency power via the emergency plug. This is
attached to the instruction manual.
Fault
Possible causes
Remedy
Living area battery is not
No mains voltage
Switch the cut-out in the
Living area battery is not
charged during 230 V
No mains voltage
Switch the cut out in the
vehicle back on; check the
g
g
operation (battery voltage
permanently below
;
mains voltage
permanently below
13.3 V)
Defective Electroblock
Call customer service
Living area battery over-
loaded during 230 V
operation (battery voltage
permanently above
14.5 V)
Defective Electroblock
Call customer service
Starter battery is not
No mains voltage
Switch the cut-out in the
Starter battery is not
charged during 230 V
No mains voltage
Switch the cut out in the
vehicle back on; check the
g
g
operation (battery voltage
permanently below
;
mains voltage
permanently below
13.0 V)
Defective Electroblock
Call customer service
Living area battery is not
charged whilst driving
(b tt
lt
b l
Defective alternator
Have the alternator
checked
g
g
(battery voltage below
13.0 V)*
No voltage at D+ input
Have the fuse and wiring
checked
Defective Electroblock
Call customer service
Living area battery is over-
loaded whilst driving (bat-
tery voltage permanently
above 14.3 V)
Defective alternator
Have the alternator
checked
The fridge does not work
whilst driving*
No power supply to the
fridge
Have the fuse and wiring
checked
g
Defective Electroblock
Call customer service
Defective fridge
Have the fridge checked
Solar charger does not
Solar charger not plugged Plug the solar charger in
Solar charger does not
work (power supply and
engine are off)*
Solar charger not plugged
in
Plug the solar charger in
engine are off)*
Defective fuse or wiring
Have the fuse and wiring
Defective fuse or wiring
Have the fuse and wiring
checked
Defective solar charger
Have the solar charger
checked
Emergency operation