Electroblock EBL 220-4 A / EBL 220-4 with OVP instruction manual
8
Issued: 21.06.2010
811.592 BA / EN
Y
ATTENTION!
Permitted input voltage exceeded!
Will damage the consumers connected to the system:
F
Never run a solar charger supplied by Schaudt without a battery being
connected to the system.
F
Unplug the “+ solar-cell” connector on the solar charger first if the
battery is going to be changed or removed.
³
The living area battery must be fully charged before closing the system
down.
The living area battery is then protected against total discharge. This applies
only if the battery is intact. Follow the instructions of the battery manufactu-
rer. The shut down system requires approx. 4 Ah a month.
Disconnect the living area battery from the 12 V power supply if you are not
going to use the motorhome for a lengthy period (i.e. during the winter). The
system is equipped with a battery isolator that completely isolates the living
area battery (electrically) from the vehicle. Battery isolation is activated from
the DT/LT ... control and switch panel (see DT/LT control and switch panel
instruction manual).
³
12 V main switch on the DT/LT ... control and switch panel must be
switched off.
³
Activate battery isolation on the DT/LT ... control and switch panel.
³
Pull out the fuse for the AES refrigerator.
Y
The living area battery can also be charged using the internal charger
module, an auxiliary battery charging unit, the solar charger and the alter-
nator when the battery isolation is activated.
³
The living area battery must be fully charged before closing the system
down.
³
Remove the clamps from the battery terminals.
³
Remove the “+ solar-cell” connector on the solar charger.
Y
The battery alarm is no longer active.
Closing down for up to
6 months
Disconnecting the living
area battery from the
12 V mains supply
Closing down for more
than 6 months