Battery selector switch
The switching option provided by the battery selector switch ensures optimum
charging of the two different types of battery, lead acid and lead gel. The
switch must be set to the correct battery type: lead acid or lead gel.
❱
For a lead gel battery, set the battery selector switch to "Lead-Gel".
❱
For a lead acid battery, set the battery selector switch to "Lead-Acid".
12 V main switch (on the
control and switch panel)
The 12 V main switch on the control and switch panel switches all consumers
on and off.
The only exceptions are the entrance step, frost protection valve and AES
refrigerator.
For more information, see the instruction manual of the control and switch
panel.
6.2 Additional functions
Automatic switch function
for awning light
The awning light only works when the power supply is on, the vehicle engine
is off and the D+ connection is not live.
Automatic switch function
for refrigerator
This relay supplies the refrigerator with power from the starter battery when
the vehicle engine is running and the D+ connection is live. An AES refriger-
ator is powered by the living area battery when the vehicle engine is switched
off.
Mains charging of starter
battery
This feature provides an automatic float charge for the starter battery at up to
2 A when the 230 V mains is connected to the Electrobloc.
▲
When the battery cut-off switch is switched off the frost protection valve on
the heater system opens automatically. Water may be lost. For more infor-
mation, see the instruction manual of the heater system.
▲
There is a danger of explosion due to the formation of detonating gas if
the battery selector switch is incorrectly set.
▲
An incorrectly set battery selector switch damages the living area battery.
▲
Disconnect the Electrobloc from the mains before adjusting the battery
selector switch.