![Schaudt CSV 416 Operating Instructions Manual Download Page 15](http://html.mh-extra.com/html/schaudt/csv-416/csv-416_operating-instructions-manual_1210310015.webp)
Operating Instructions Caravan-charging system CSV 416
15
Date: 30.05.2021
8050111 BA / EN
I (”Bulk”)
Main charge with maximum 20 A charging current, electronically limited, up
to end-of-charge voltage U
VL
. Start of charge also for completely discharged
batteries.
Uo (”Absorption”)
Automatic switchover to full charging with constant voltage U
VL
. The dura-
tion of the full charge phase is based on the battery type (is set from an EBL
... control panel connected). This sets a full charge time and minimal charge
current.
U (”Float”)
Automatic switchover to trickle charging with constant U
EL
. In the trickle
charge phase, a constant voltage is applied to the charger module output.
U (”Standby”)
Further reduction of charge voltage to U
R
. This phase lasts time t
R
.
U (”Refresh”)
A refresh with full charge voltage U
VL
for time t
F
is started once idle phase
time t
R
has expired.
Y
All voltages and times are dependent on the battery type used. These
parameters are set automatically by setting the correct battery type:
Phase 1
Phase 2
Phase 3
Phase 4
Phase 5
I (”Bulk”) Uo (”Absorption”)
U (”Float”)
U (”Standby”)
U (”Refresh”)
Battery
type
I
max
U
VL
t
VL
U
EL
t
EL
U
R
t
R
t
F
Lead-acid
28 A
14.40 V
4 hour
13.40 V
72 hour
13.00 V 120 hour
1 hour
Lead-gel/A
GM1
28 A
14.40 V
8 hour
13.80 V
72 hour
13.20 V 120 hour
1 hour
AGM 2
28 A
14.70 V
4 hour
13.70 V
72 hour
13.20 V 120 hour
1 hour
LiFePo4*
28 A
14.40 V
2 hour
13.80 V contin-uo
us
--
--
--
* Only batteries with their own battery management system fitted may be
used.
6.3 Environmental parameters
-20
C to +45
C
-20
C to +70
C
IP 20
Operation in dry environment only
CE mark
7
Maintenance
The CSV 416A caravan charging system requires no maintenance.
Clean the caravan charging system using a soft, slightly damp cloth and mild
detergent. Never use spirit, thinners or similar substances. Do not allow fluid
to ingress the caravan charging system.
No part of this manual may be reproduced, translated or copied without
express written permission.
Operating temperature
Storage temperature
Protection rating
Humidity
Yes
Cleaning
E