Operating manual for caravan-charging system CSV 410
9
Date: 20.02.2020
8050102 BA / EN
Y
CAUTION!
Battery discharge
Towing vehicle can no longer start:
F
Switch off the ignition when the towing vehicle is stationary.
5.3 Changing the battery
Y
CAUTION!
Use of incorrect battery types or incorrectly rated batteries.
Will damage the battery or the devices connected up to the caravan char-
ging system:
F
Batteries should only be changed by qualified personnel.
F
Follow the battery manufacturer’s instructions.
F
The caravan charging system is to be used solely for connecting the
12 V power supply to 6-cell lead-gel or lead-acid batteries. Never use
non-approved battery types such as NiMH batteries.
Y
Normally only batteries of the same type and capacity should be used,
i.e. the same as those installed by the manufacturer.
Y
It is possible to swap lead acid batteries with lead gel batteries. You can-
not change over from lead-gel to lead-acid batteries. Contact the vehicle
manufacturer for more information.
Disconnect the battery from the caravan charging system by switching
the 12 V main switch off.
Unhitch the caravan from the towing vehicle.
Replace battery.
After changing the battery, recheck which type of battery has been inser-
ted.
Y
DANGER!
Incorrect setting of the battery selector switch.
Risk of explosion due to build up of explosive gases:
F
Move the battery selector switch to the correct position.
Y
CAUTION!
Incorrect setting of the battery selector switch.
Damage to the battery.
F
Move the battery selector switch to the correct position.
Disconnect the caravan charging system from the mains before resetting
the battery selector switch.
Move the battery selector switch (Fig. 2, Pos. 21) to the correct position
using a thin object (e.g. a ballpoint pen):
F
Lead gel battery: Set the battery selector switch to ”Lead-gel”.
F
Lead acid battery: Set the battery selector switch to ”Lead-acid”.
Start up the system as described in Section 5.2.
Operation on towing
vehicle
Changing the battery
Starting up
the system