5.1.3 Connect pump (option)
For the pump to be switched on, the 12V supply voltage must first be swit-
ched on (see Section 5.1.2 for the main supply).
Move the switch with the pump
symbol upwards.
The supply voltage for the water pump is enabled:
F
The pump may switch on briefly (e.g. in a pressure system).
F
In other systems, the pump is enabled by the water tap contacts.
Move the switch with the pump
symbol downwards.
5.2 Starting up the system
Y
CAUTION!
Incorrect settings on the caravan charging system.
Damage to connected devices. Therefore prior to starting:
F
Ensure that the battery selector switch (Fig. 2, Pos. 21) is set to the
correct position for the battery installed.
Press rocker switch
(12V main switch) so that it is briefly in the ”I” po-
sition (ON).
The 12 V main switch switches all consumers on and off (exception: the
fridge controller electronics).
Y
CAUTION!
Exceeding the thresholds of the 230V mains supply.
Will damage the caravan charging system, 12 V consumers or other con-
nected devices:
F
Do not connect a generator until it is running smoothly.
F
It is essential that the generator conforms to the specifications of the
mains supply.
F
Do not connect the caravan charging system to the onboard mains
voltage on car ferries (non-problematic mains voltage cannot always
be guaranteed on car ferries).
The use of an upstream overvoltage protection device is recommen-
ded.
Y
CAUTION!
No battery buffer function
Damage to connected devices:
F
Do not operate solar regulator without battery connected.
Switching on
Switching off
12V main switch
Generator operation and
passenger vehicle
ferries
Operation with solar
regulator