background image

Installation, Mounting and Maintenance DISA-H

Z11/31 - 3

Construction subject to change.

No return possible!

18.02.2013

Version:

Safety instructions

Prior to installation and commissioning of this device, please

read completely through this manual. Please observe in partic-

ular the regulations and operating instructions  containing the

hazard symbols and safety signs. Non-observance can result

both in damage to the device and personal injuries.

If, after reading through the manual, you have further questions,

please contact the manufacturer or the local sales office.

General information

SCHAKO shall not give any warranty for damage resulting from:

Warranty

The device warranty will be for two years starting from the

handover date and shall apply to all production faults. Electric

components are excluded from the device warranty. However,

they are covered by the corresponding warranty of the relevant

manufacturer 

Also excluded from the warranty is damage to the device unit

caused by components that are not part of the device itself.

The warranty only covers the return and replacement of defec-

tive materials.

Recycling

- The inspection, installation, hydraulic connection and

commissioning of the device must be carried out by qual-

ified skilled personnel only in compliance with the current

regulations.

- Electric and hydraulic connections and their correct func-

tioning are the responsibility of the installer.

- Do not change any control or safety elements without pri-

or approval by the manufacturer or the local sales office.

- Improper use caused by ignoring the instructions given in

this manual

- Non-observance of the operating conditions of the device.
- Installation and maintenance by personnel without proper

qualification.

- Improper use of the device or operation under conditions

not conforming to the manual.

- Use of spare parts that are not original spare parts.

It is recommended recycling the components of

the device

at the end of the device service life as completely

as possible 

or use them for a different purpose.

Components that cannot be recycled must be

properly disposed of by an authorized disposal

company in accordance with current legal regula-

tions.

It is recommended keeping this manual at a safe lo-

cation after installation and use it for future mainte-

nance activities.

Hazard warning

Important information

Safety information

Recycling

Summary of Contents for DISA-H Series

Page 1: ...Ferdinand Schad KG Steigstra e 25 27 D 78600 Kolbingen Telefon 49 0 74 63 980 0 Telefax 49 0 74 63 980 200 info schako de www schako de Installation Mounting and Maintenance DISA H...

Page 2: ...ormation 4 Identification of the delivered model 4 Function 4 Installation and commissioning 5 Operating conditions 5 Material reception 5 Transport lifting and handling 5 Storage 5 Installation 6 Mou...

Page 3: ...acement of defec tive materials Recycling The inspection installation hydraulic connection and commissioning of the device must be carried out by qual ified skilled personnel only in compliance with t...

Page 4: ...nsist of copper pipes 12 mm in thickness aluminium ribs diffuser system and a steel frame Grille 3 Louvre grid for supply air and return air optional Hydraulic connections 4 Upon customer request the...

Page 5: ...tion it must be stored according to the following instructions Coolant or heating fluid water or glycols ethylene or pro pylene at a concentration below 60 Water inlet temperature above the dew point...

Page 6: ...As standard the cooling circuit pipes are attached on the outside and the heating circuits at the centre of the register 4 pipe Hydraulic connections DISA H H 2 pipe Hydraulic connections DISA H HT 4...

Page 7: ...rks During in stallation the manufacturer s specifications must be observed Temperature controls The temperature controls are mounted in accordance with the selected model This is why the instructions...

Page 8: ...onnected to the hydraulic cir cuit with flexible hos es of sufficient length Hydraulic connections were tightened properly and exhib it no leaks Connecting and fastening elements have been sufficientl...

Page 9: ...and the following formula can be used to to determine the volumetric flow V l s Primary air flow Ps Pa Static pressure The K value is taken from the following table Air density 1 2 kg m3 VZU m3 h supp...

Page 10: ...r Install thermostat in a different place Clogging of the cooling heating register Clean the register in accordance with the maintenance instructions The unit is losing water Condensate in the registe...

Page 11: ...100 SAFETY OF MACHINERY Safety of Machinery Basic terms general principles of design Part 1 Basic terminology methodology DIN EN ISO 12100 SAFETY OF MACHINERY Safety of Machinery Basic terms general p...

Reviews: