Line Scan Camera SK8100U3JRC Manual (07.2015) • shar
ed_AdvancedSyncCtrl(2)_ExampleTimingDiagram_ML.indd (07.2015)
23
4 Advanced SkLineScan Software Functions
SK8100U3JRC
Instruction Manual
(07.2015)
© 2015
Schäfter + Kirchhoff GmbH
•
Hamburg
•
Trigger on falling edge
of SyncA
•
SyncB = low active
•
direction detection = on
•
hysteresis = 0
Sync Control Register:
'10000xxx'b
B
1)
•
Trigger on falling edge
of SyncA
•
SyncB without function
•
direction detection = off
•
hysteresis = 0
Sync Control Register:
'00000xxx'b
A
1)
•
Trigger on falling edge
of SyncA
•
SyncB = low/high active
•
direction detection = on
•
hysteresis = 0
Sync Control Register:
'11000xxx'b
C
1)
•
Trigger on 4 edges
of SyncA and SyncB
•
direction detection = on
•
hysteresis = 0
Sync Control Register:
'11100xxx'b
D
1)
•
Trigger on 4 edges
of SyncA and SyncB
•
direction detection = on
•
hysteresis = 4
Sync Control Register:
'11101xxx'b
E
2)
1)
1)
1)
machine holdup oscillation
4 Advanced SkLineScan Softwar
e Functions
Example Timing Diagrams of Advanced Synchronization Control
Annotations:
SyncA
= LINE SYNC A (external line synchronization input, I/O connector)
SyncB
= LINE SYNC B (external line synchronization input, I/O connector)
Count
= internal counter
Trigger
= Generated trigger pulses from the Trigger Control stage. The signal goes to the Trigger
Divider stage inside the camera. For setting the divider use the V
yyyyy
<CR> command or the
'Divider' input field in the
4.1 Camera Control by Commands, p. 20
.
1) direction changed
2) glitch