Line Scan Camera SK2048GJR-4L Manual (09.2016) • shar
ed_CameraContr
ol(5)_Advanced-Sync-Ctrl_ML.indd (09.2016)
23
SK2048GJR-4L
Instruction Manual
(09.2016)
© 2016
Schäfter + Kirchhoff GmbH
•
Hamburg
4 Advanced SkLineScan Software Functions
•
Trigger on falling edge
of SyncA
•
SyncB = low active
•
direction detection = on
•
hysteresis = 0
Sync Control Register:
'1000 0xxx'b
B
1)
•
Trigger on falling edge
of SyncA
•
SyncB without function
•
direction detection = off
•
hysteresis = 0
Sync Control Register:
'0xxx xxxx'b
A
1)
•
Trigger on falling edge
of SyncA
•
SyncB = low/high active
•
direction detection = on
•
hysteresis = 0
Sync Control Register:
'1100 0xxx'b
C
1)
•
Trigger on 4 edges
of SyncA and SyncB
•
direction detection = on
•
hysteresis = 0
Sync Control Register:
'1110 0xxx'b
D
1)
•
Trigger on 4 edges
of SyncA and SyncB
•
direction detection = on
•
hysteresis = 4
Sync Control Register:
'1110 1xxx'b
E
2)
1)
1)
1)
machine holdup oscillation
Example Timing Diagrams of Advanced Synchronization Control
Annotations:
SyncA
= LINE SYNC A (external line synchronization input, I/O connector)
SyncB
= LINE SYNC B (external line synchronization input, I/O connector)
Count
= internal counter
Trigger
= Generated trigger pulses from the Trigger Control stage. The signal goes to the Trigger
Divider stage inside the camera. For setting the divider, use the V
yyyyy
<CR> command or the
4.1 Camera Control by Commands, p. 20
.
1) direction changed
2) glitch