KIT OVERVIEW

The list below references the parts provided when 
assembling the HVAC Adapter onto a ScentDirect 
system. The ScentDirect System and Cartridge are 
packaged separately. 

PARTS INCLUDED

1.  PVDF Tubing (6’ x ¼” OD x .17” ID)
• 

30200189  x 6 [both ends sealed]

2.  HVAC Adapter Cap    
• 

30400032

3.  4x Self Tapping Screws 12x1
• 

30210304

4.  Duct Mount Assembly
5.  3 - Zip Tie
• 

30217001

6.  Replacement 4004 control board with HVAC 

programming

7.  Screw - 4-24  x ¾”
8.  Duct pressure sensor wired connector for PCB
9.  Duct Pressure sensor
10.  Duct sensor probe [sheet metal screws not 

shown]

11.  Screw terminal connector 
12.  Clear soft plastic tubing for sensor 
13.  Jacketed cable for sensor - 25’

1

2

3

4

6

8

10

9

7

11

5

Summary of Contents for ScentDirect HVAC-S

Page 1: ...rately PARTS INCLUDED 1 PVDF Tubing 6 x OD x 17 ID 30200189 x 6 both ends sealed 2 HVAC Adapter Cap 30400032 3 4x Self Tapping Screws 12x1 30210304 4 Duct Mount Assembly 5 3 Zip Tie 30217001 6 Replace...

Page 2: ...located Fasten the screw terminal connector to the machine with the screw Part 7 from the kit FIG 1 4 Unlatch and open the door of the SDD4004 system to access the control panel 5 Use the 2 Phillips s...

Page 3: ...the PCB box through the hole at the rear along with the other wire connectors Feed the wires through the slot in the fan housing FIG 2 11 Pass the wires up and out through the slot shown in the top o...

Page 4: ...wires are connected to the 2 pins on the control board The 3 pin connector on the control board will be left unused 15 Reattach PCB faceplate assembly to SDD4004 and secure with the 4 flathead screws...

Page 5: ...ing through DUCT MOUNT as shown FIG 4 6 Secure the tubing to the Duct Mount as shown using zip ties The opening must be just past the end of the metal rod and the tubing must be secure to allow the ro...

Page 6: ...itch 2 Find a location at least 5 times the diameter downstream from any elbows obstructions fans or any significant change in duct area For a round duct with a 10 diameter the insertion point needs t...

Page 7: ...together at the connector the red wire on the cable to the side of the connector with the red wire from the machine and tighten securely with a fine slotted screwdriver 9 IMPORTANT Check that the HVA...

Page 8: ...For further assistance please contact ScentAir Technical Services North America 1 704 504 2320 Europe 33 0 5 62 57 63 20 Asia 852 356 378 42 techservices scentair com...

Reviews: