WL-410/XB
User Guide
Wireless
Wind Alarm System
Page 1: ...WL 410 XB User Guide Wireless Wind Alarm System ...
Page 2: ...868 MHz radio frequency module is installed in the receiver of model WL 410 and WL 410XB In mode WL 410XB an additional Bluetooth Low Energy chip is installed in the receiver to enable smartphone communication functionality WL 410XB sensor output power is stronger 14 dBm than WL 410 allowing a longer transmission distance An optional 4 20 mA current loop module is available to both WL 410 and WL 4...
Page 3: ...ing height and when there is no obstacle between the sensor and the display unit The range is much shorter inside buildings Normally the signal can be received through two to three walls Address The correspondent sensor address has been present at the factory Always set the address to correspond to the address of the sensor from which the receiver will receive data Address of the sensor is indicat...
Page 4: ...al is lost for more than 30 seconds the No data appears on the display indicating that the receiver doesn t receive data from the sensor sensor OFF or out of range The threshold wind speed of Pre Alarm 1 Pre Alarm 2 and Max Alarm can be configured via setting menus Please see the section Settings for more details Pre Alarm 1 triggers one LED indicator sit beside the LCD screen Pre Alarm 2 triggers...
Page 5: ...ight will start blinking and buzzer will sound with interruptions When the sound alarm is activated you can mute it by pressing upper key for 3 seconds Please see section Settings for more details Relay 1 When set value exceeds the relay 1 will activate red light will flash and buzzer will continuously sound When sound alarm is activated you can mute it by pressing upper key for 3 seconds Please s...
Page 6: ...s or newer In Application setting menu always set the address corresponding to the address of the sensor from which you wish to receive data Address of the sensor is indicated on the label and in the interior of the battery compartment For example enter the sensor address showed on the label e g 78 Once it s paired the data will be automatically transmitted to the mobile device iOS Wind Smart Andr...
Page 7: ...3 seconds or leave the device alone for 1 minute The contents of the display are shown above Note in both bar graphs the max alarm value set by user is always on the 3 4 bar height One icon not shown in the photo is data packet receiving indicator and it flashes by the side the signal strength 8 hours peak wind speed history graph with 5 minutes resolution each row presents the peak wind speed dur...
Page 8: ...tting menu If the password protection is active enter correct pass word The options of settings are shown on display 2 Select the option by using up and down keys and press SET key to enter into selected option 3 By up and down keys select the parameter you wish to adjust and press SET key to enter into selected parameter The adjustable parameter blinks 4 By up and down key adjust the parameter va...
Page 9: ...peed drop below preset level Relay Normal Normal interleaved Inverted operation of relay Factory default Settable range Description Wind speed 42 km h 1 50 m s Pre alarm 1 limit On delay 0 sec 0 600 sec Minimum time of exceed wind speed to activate the pre alarm 1 Off delay 0 min 0 60 min Delay of alarm switch OFF after wind speed drop below preset level Relay Normal Normal interleaved Inverted op...
Page 10: ...utput 180 km h 10 50 m s Wind speed at 20 mA output 4mA 0 km h 20 mA seted value wind speed applicable only at model with additional 4 20 mA output Password No No Yes 0000 9999 Activation of password protection and setting of password Sound alarm On On Off Switching sound alarm ON and OFF Language English English French Language selection Wind speed calibration factor 0 0 Calibration factor for wi...
Page 11: ...le Receiver housing Sensor dimension Receiver dimension Mounting Bluetooth LE 2 x precision stainless steel ball AL PVC PA Nylon ABS IP65 Height 210 mm cup to cup diameter 120 mm 150 x 80 x 55 mm Mounts on a pipe with ø20 mm outside diameter WL 410 WL 410XB WL 410XB 4 20mA Yes Range is up to 40 m 0 6 50 0 m s m s km h knots mph 0 1 m s 3 Selectable 2 s 10 s 30 s 12 24 V DC 300 mA max 1 A 12 V DC 1...
Page 12: ... cause stains such as dirt ink makeup or lotions To clean Disconnect all cables and turn instrument off Use a soft lint free cloth Avoid getting moisture in openings Don t use cleaning products or compressed air Operating temperature The instrument is designed to work in ambient temperatures between 5 and 40 C 41 and 104 F and stored in temperatures between 10 and 60 C 14 and 140 F The instrument ...
Page 13: ...patibility has been tested in accordance with EN61326 2 2006 Accessories Magnetic mounting assembly receiver YAGI antenna with 3 m cable Outdoor antenna with 3 m cable Self leveling mounting assembly sensor Magnetic mounting assembly sensor Spare parts Wind cup is replaceable and can be ordered separately To help in mounting and to enhance the transmission distance you may need the following acces...
Page 14: ...cessary by improper use including adaptation to particular applications not foreseen in the instructions manual or improper combination with incompatible accessories or equipment Repairs made necessary by improper shipping material causing damages in transit Repairs made necessary by previous attempts for repair carried out by non skilled or unauthorized personnel Instruments for whatever reason m...
Page 15: ...Scarlet Tech Co Ltd 2015 Scarlet Tech Co Ltd All rights reserved 4F 3 No 347 HePing E Rd 2nd Sec DaAn District Taipei City 106 Taiwan E mail info scarlet com tw www scarlet tech com version 2019 09 ...