Mistral Operating Instructions
Part No. SCAZ037980 v6.0.2
22
E&OE
Dust suppression
Filling the water tank
Attach the appropriate coupling and water hose to the filler aperture
q
and fill until the blue
float reaches the top of the water level sight tube
w
(use clean water).
Using the low pressure water system
The low pressure water is used on the, side brush(es), suction tube(s), and central (wide sweep)
brush.
To operate any of these functions the relevant button(s) on the main panel must be selected
when in sweep mode.
A shut-off valve is positioned between the pump and tank and must be open when the system
is in use
e
.
Each side brush is fitted with a shut off valve
r
.
It is vital that the water system is drained totally if the air temperature is expected to fall
to 0°c or below.
Draining the system
1.
Open tank drain valve
t
.
2.
Open drain valve at bottom of water filter
y
, located on opposite side of the leg on
which the low pressure water pump is mounted.
3.
Open all brush shut-off valves
r
.
Due to customers requirements, other water features may be present but not mentioned in
this publication.
2
4
5
1
3
6