Introduction
Page 8
Max internal radio sounders (Note 4)
2
4
4
5
20
Max Wireless Access Modules
2
4
4
5
20
C
a
s
e
Control unit case
Plastic
Plastic
Plastic
Metal
Metal
Battery (Note 7)
1 (2.2Ah)
1 (7Ah)
1 (7Ah)
1 (7Ah) 1 (17Ah)
Power Supply Unit (PSU)
0.5A
1.0A
1.0A
1.0A
2.0A
PSU current reserved for battery charging
100mA
180mA
180mA
180mA
750mA
Back and lid tamper
Yes
Yes
Yes
Yes
Yes
S
o
ft
w
a
re
Users
20
30
50
50
200
Part sets (including per partition in partitioned mode)
3
3
3
3
3
Max partitions (see Note 1)
0
4
4
5
20
Mandatory log events
250
750
750
750
1500
Non-mandatory log events
50
250
250
750
1500
Calendar set events
0
10
10
10
50
Calendar set exceptions
0
30
30
30
30
Max shunt groups
0
4
4
5
20
Max simultaneous keypad sessions
1
4
4
5
10
Web interface
Yes
Yes
Yes
Yes
Yes
SecureConnect and web browser interface
Yes
Yes
Yes
Yes
Yes
Firmware update via web interface, cloud auto update,
or SD card
Yes
Yes
Yes
Yes
Yes
Firmware update via USB port
Yes
No
No
No
No
Multilanguage support (-EU variant)
Yes
Yes
Yes
Yes
Yes
Note 1:
Each partition can have three part-set levels. Partitions are not available for i-on
Compact.
Note 2:
The maximum number of wired keypads is the same as the maximum number of
bus devices, but decreases by one for each expander or KEY-RKPZ that is added. A
KEY-RKPZ is a radio keypad that uses a KEY-RKBS base station wired to the bus. Up to
two KEY-RKPZ keypads can connect to the same base station, but this feature cannot be
used to increase the total number of keypads beyond the limit shown in Table 1.
Note 3:
The maximum number of i-rk01 and KEY-RAS radio keypads is in addition to the
maximum number of wired keypads.
Note 4:
The maximum number of external radio siren/strobe units is in addition to the
maximum number of internal radio sounders.
Note 5:
The system-wide maximum number of outputs includes on-board radio outputs,
on-board relay and transistor outputs and outputs provided by expanders, keypads and
other peripherals. It does not include plug-by outputs.
Note 6:
The maximum number of on-board zones is for Fully-Supervised Loop (FSL) or
2-wire Closed Circuit (CC) wiring. If 4-wire CC wiring is used, the maximum number of
on-board zones is halved, unless an optional ADP-10CC board is fitted.
Note 7:
The maximum sizes of batteries are given. A battery is supplied only for i-on
Compact.
Note 8:
The i-onG3MM has two busses. The limit of 50 devices is the combined total of all