Installing i-on Control Units
Page 32
Figure 11. i-on30R+ and i-on40H+: Mains cable routing
Step 2: Remove the lid of the control unit
Release the two screws on the front of the lid, then lift it off.
Step 3: Fit the tamper switch and shroud
Fit the tamper switch assembly through the slot in the back of the case (Figure 12).
Also, for added security, fit the tamper shroud to the wall so that when you mount the
control unit, the shroud will surround the arm of the tamper switch.
Figure 12. i-on30R+ and i-on40H+: Fitting the tamper switch and shroud
Step 4: Mount the control unit
Mount the control unit in the orientation shown in Figure 10 using at least 4 fixing holes
and minimum 40mm long No10(5mm) screws. Use only the designated cable-entry holes.
Step 5: Connect all wired devices
Connect all wired devices except the battery, as shown in Figure 9.
If you are using a plug-
on module, fit and connect the device as described in the module’s
installation instructions.
Do not mount mains
cable behind the aerials
Tamper switch:
Ensure correct
orientation
Case of control unit
Tamper sleeve
Tamper shroud
(fit to wall, long