Scantronic EXP-W10 Installation Instructions Manual Download Page 2

Page 

2

UK

Introduction

 

The EXP-W10 is a wired expander for use with 
i-on intrusion systems.
Features:

 

Provides 10 on-board wired zones.

 

Connects directly to the bus.

 

Designed for compatibility with security 
grade 3.

 

Compatible with a wide variety of wired 
detectors including PIR sensors, smoke 
detectors, hold-up devices, perimeter 
sensors and door contacts.

 

Provides four open-collector outputs (to 
control external equipment), which can 
be converted to relay outputs using the 
optional i-rc01 relay card.

 

Engineer keypad port.

 

Cover and back tamper detection.

Caution: If you need to handle the PCB in the 
unit, take standard precautions to prevent 
damage by static electricity.

Step 1: Choose a location

The unit must be located:

 

Within the protected area (but not in an 
entry or exit zone).

 

Ideally, more than 2 metres from the floor.

 

Out of sight of potential intruders.

 

On a wall or other flat surface to discourage 
tamper attempts from the rear.

Step 2: Install cabling

Note:

 

Before you install any wiring, disconnect 
all power to the control unit, including the 
battery.

 

In general, the expander requires 7/0.2 
unscreened alarm cable. Screened cable 
may be needed if the site has high levels of 
radio interference.

 

Keep keep bus cable separate from any 
other wiring.

 

For full details of wiring requirements, 
please refer to the control unit’s 

Installation 

Manual

.

Step 3: Mount the backplate

1. Loosen the screw on the front cover and lift 

off the cover.

2. Mount the backplate to the wall (Figure 1).

Step 4: Connect all wiring

Connect all wiring to the PCB (Figure 1). See 
the later sections for connection details.

Step 5: Address and configure the 

expander

WARNING: During initial power-up, keypad 
sounders and any internal loudspeaker may 
give an alarm tone. If you are working at the 
top of a ladder, make sure that the sudden 
noise does not startle you and cause a fall.
With the cover of the expander still off, 
power-up the control unit.
Use the 

Wired Expanders option in the 

Installer menu to set the address of the 
expander (see “Address button”) and 
to configure other settings such as the 
expander partitions (if applicable). For further 
information, please refer to the 

Configuration 

Guide.

PCB links, connectors and LEDs

The following sections provide information 
about the links, connectors and LEDs shown 
in Figure 1.

LED display

This displays address and diagnostic 
information. Please see “

Bus”.

0V/12V AUX terminals

The 0V/12V AUX terminals provide power 
for external equipment. The terminals are 
protected by a resettable fuse. 

Wired zone connections

You can connect up to 10 wired detectors (0 to 
9) to the EXP-W10 using the Fully-Supervised 
Loop (FSL), 4-wire Closed Circuit (CC) or 2-wire 
CC wiring method (Figure 1). All detectors on 
the same EXP-W10 must use the same wiring 
method, but if FSL is used, each detector can 
have different resistor values.
Please refer to the 

I-on Series Installation 

Manual if you want to use two detectors per 

zone.
Anti-mask detectors use 2k2 EOL, 4k7 alarm, 
and 2k2 anti-mask resistors (see the 

i-on Series 

Installation Manual).
The total wiring and switch resistance must be 
less than 100 Ohms (EOL resistor shorted in 
the case of FSL).
By default, the system assumes normally-
closed contacts. Detectors with normally-open 
contacts must be programmed with the 
“Inverted” attribute set.

Engineer keypad port

You can use an engineer keypad to configure 
the system, rather than a keypad on the bus. 
An engineer keypad does not need an address.
This port has the same purpose as an engineer 
keypad port at the control unit. 

Bus

Connect the expander to the bus. Refer to 
“Step 2 Install Cabling” for guidance about 
bus cabling. See also “LED display” and 
“Engineer keypad port”.

RS485 bus termination link

If the EXP-W10 is at one end of the chain of 
bus devices, fit a jumper across this link. 
RS485 termination can improve performance 
in electrically noisy environments.

Address button

With the tamper switch open, you can use this 
button to:

 

Request the control unit to assign an 
address to the EXP-W10 − Select 

Address 

Bus Device in the Installer menu, then press 

and hold the button until you see the new 
address on the LED display (for example, 
“1-” followed by “01” means bus 1 device 
01). Press and hold again if you want to 
select the next free address.
A continuous beep approximately once per 
second indicates that the EXP-W10 is waiting 
for an address from the control unit.

 

View the current address of the EXP-W10 on 
the LED display −  Press once (“--” means 
the device has no address).

 

Delete the address from the EXP-W10 − 
Press and hold while applying power.

With the tamper switch closed, pressing 
the Address button displays a sequence of 
diagnostic information on the LED display, 
such as:

 

“r3” then “00” − Software version 3.00.

 

“t” − EXP-W10 type (tC = 4-wire CC).

 

“12” then “-4” − Bus voltage of 12.4V.

 

“0-” then “12” − AUX output current of 
0.12A.

Disable tamper link

Connecting a jumper across the link disables 
the tamper switches.. You may want to do 
this if, for example, the EXP-W10 is inside 
another tamper-protected enclosure (such as 
the control unit).

i-rc01 port

You can convert the four open-collector 
outputs to relay outputs by connecting an 
i-rc01 relay card to the i-rc01 port or directly to 
the output terminals. 
Please refer to the i-rc01 instructions for 
further information.

Open-collector wired outputs

The four open-collector transistor outputs 
can be used to switch external equipment 
on or off. 
By default, the outputs are 12Vdc when 
inactive and 0V when active (this can be 
reversed from the Installer menu). 
Note: An i-rc01 card can be used to convert 
the outputs to relay (voltage-free) outputs.

Loudspeaker connections

If fitted, a loudspeaker mimics alarm tones 
and repeats setting and entry tones. The 
loudspeaker must be min 16 Ohms. 
Note: 

 

A loudspeaker is not a warning device as 
described by EN50131-4.

 

You can set the loudspeaker volume and 
partitions from the Installer menu. 

Heartbeat LED

The number of flashes of the heartbeat LED 
indicates the bus status:

 

One flash: No faults.

 

Two flashes: Not receiving bus data.

 

Three flashes: No assigned address.

 

Four flashes: There is bus activity, but not 
for the EXP-W10.

Fuses

The PCB includes resettable fuses to protect 
the AUX and BUS 12V outputs. The fuses 
can be reset by removing and reconnecting 
the load.

Maintenance

The only maintenance required is cleaning 
and an annual test of the expander using the 
Test menu at the control unit.
Clean the outside of the case using a soft 
dry cloth. Do not use water, solvents or  any 
proprietary cleaning agents.

Specifications

Supply Voltage: 12Vdc.
Quiescent Consumption (max): 20mA (display 
off, no AUX load and no loudspeaker).
Output: Open collector, 12Vdc when inactive, 
0V when active. Combined total for all outputs 
is 500mA max (fuse protected).
Dimensions: 230 x 144 x 44 mm (h,w,d).
Weight: 420g.
Operating Temp.: -10°C to +55°C.
Max Relative Humidity: 93%, non-condensing.
Case Material: ABS.
Intrusion Standards: EN 50131-3:2009 grade 
3; PD6662:2017.

Summary of Contents for EXP-W10

Page 1: ...us RS485 Terminazione Bus RS485 RS485 busafsluiting d Engineer keypad port Bedienteil Port fürTechniker Port de clavier technicien Porta per tastiera tecnica Poort voor monteurstoetsenbord g Address button Adresstaste Bouton Adresse Pulsante indirizzo Adres knop b 0V 12Vdc AUX i i rc01 port i rc01 Port Port i rc01 Porta i rc01 i rc01 poort a LED display LED Display Afficheur à LED Display a LED LE...

Page 2: ...igure the system rather than a keypad on the bus An engineer keypad does not need an address This port has the same purpose as an engineer keypad port at the control unit e Bus Connect the expander to the bus Refer to Step 2 Install Cabling for guidance about bus cabling See also LED display and Engineer keypad port f RS485 bus termination link If the EXP W10 is at one end of the chain of bus devi...

Page 3: ...ing power facilities or claims against the purchaser or user by its customers resulting from the use of the information recommendations and descriptions contained herein The information contained in this manual is subject to change without notice 2020 Eaton Eaton Security House Vantage Point Business Village Mitcheldean GL17 0SZ www touchpoint online com Product Support UK Tel 44 0 1594 541978 ava...

Page 4: ... VORLIEGENDEN DOKUMENTS DARF NICHT ALSTEIL ODER ZUR ABÄNDERUNG EINES VERTRAGS ZWISCHEN DEN PARTEIEN DIENEN Unter keinen Umständen ist Eaton dem Käufer oder Benutzer gegenüber vertraglich aus unerlaubter Handlung heraus einschließlich Fahrlässigkeit in Kausalhaftung oder anderweitig für etwaige besondere mittelbare Neben oder Folgeschäden oder Verluste haftbar einschließlich Schäden oder Verluste i...

Page 5: ...s d armement et d entrée L impédance du haut parleur doit être de 16 ohms minimum Remarque Un haut parleur n est pas un dispositif d avertissement tel que décrit dans la norme EN50131 4 Vous pouvez régler le volume du haut parleur et les partitions à partir du menu d installation l LED Heartbeat Le nombre de clignotements de la LED Heartbeat battement de cœur indique l état du bus Un clignotement ...

Page 6: ...ori anti maschera 2k2 consultare il Manuale d Installazione della Serie i on La resistenza complessiva di cablaggio e del relè deve essere inferiore a 100 Ohm nel caso di FSL il resistore EOL è in cortocircuito Per impostazione predefinita il sistema utilizza contatti normalmente chiusi I rilevatori con contatti normalmente aperti devono essere programmati con l impostazione attributo Invertita d ...

Page 7: ...chermde gebied maar vermijd de in of uitloopzone Bij voorkeur meer dan 2 meter van de vloer Buiten het zicht van mogelijke indringers Tegen een wand of ander plat vlak om sabotage pogingen van achteren te verhinderen Stap 2 Installeer de bedrading Opmerking Voordat u enige bedrading aanbrengt moet u de hele voeding van het controlepaneel afkoppelen inclusief de batterij De uitbreider heeft doorgaa...

Page 8: ...Specificaties Voedingsspanning 12Vdc Ruststroomverbruik max 20mA scherm uit geen AUX verbruiker en geen luidspreker Uitgang Open collector 12Vdc inactief 0V actief Totale stroomsterkte voor alle uitgangen is max 500mA beveiligd met zekering Afmetingen 230 x 144 x 44 mm h w d Gewicht 420g Gebruikstemperatuur 10 C to 55 C Max relatieve vochtigheid 93 non condensing Materiaal behuizing ABS Inbraaknor...

Reviews: