Page
2
UK
Introduction
The DET-RSDC is a dual-technology radio
device, which contains two sensors: a
magnetically-operated reed switch to detect
when a door or window is opened, and an
accelerometer to detect shock events.
The DET-RSDC operates with any Eaton
or Scantronic 868MHz narrow-band panel,
expander or receiver.
Panels with v6.01 or later firmware can
independently report the alarm status of each
sensor. If required, this feature can be used
to generate a confirmed alarm when both
sensors operate (not recommended for entry
routes), which can reduce installation time
and cost.
Note: This product must be installed
and maintained only by qualified service
personnel.
Note: Make sure you follow the mounting
instructions to avoid false alarms.
Learn the sensor
1. Take the DET-RSDC to a keypad.
2. Remove the cover (see Fig. 2).
3. Make sure that the MODE link is removed
(see Fig. 3).
4. Fit the LED link (to enable the front LED and
ease testing).
5. Fit the battery. Ensure correct polarity.
6. Use the Installer menu to add a new
detector, then press and release the tamper
switch when prompted*.
*Some previous-generation products use
infra-red (not radio) learn. In these cases,
direct the DET-RSDC LED at the learn-in sensor
of the receiver (LED link must be fitted).
Mount the sensor and magnet
See Fig. 4 to Fig 7.
Note:
•
DO NOT mount the sensor on the moving
part of the door or window. Mount vertically
on the fixed frame.
•
DO NOT mount the sensor on the hinged
side.
•
Spacers can be mounted behind the magnet
or sensor, but note that this may reduce the
sensitivity of shock detection.
•
The sensor and magnet can be positioned
face-to-face, providing:
•
The arrows on the sensor and magnet
backplates align.
•
The maximum separation between
the faces is no more than 10mm when
mounting on metal surfaces, or no more
than 15mm when mounting on non-metal
surfaces.
Radio performance
Do not mount the sensor:
•
Horizontally or upside down.
•
Near the floor.
•
Close to or on large metal structures.
•
Closer than 1m to mains wiring or metal
pipes.
•
Next to electronic equipment, such as
computers, photocopiers and other radio
equipment.
Test the sensor
Test the operation of the device. The LED (if
enabled) flashes when either sensor activates.
After testing, consider removing the LED link
to enhance security and prolong battery life.
It is recommended that you carry out shock
tests while in calibration mode (see below), as
you can both check and adjust sensitivity.
For shock testing, use an appropriate tool to
strike the extremities of the protected area.
Range is dependent on the mounting surface
and testing is essential.
Calibration mode
To check and adjust the shock sensor:
1. Enter the Installer menu.
2. Open the DET-RSDC, then press and release
the tamper switch five times within three
seconds to activate calibration mode.
A double long flash of the LED indicates
that calibration mode has started (even if
the LED link is not fitted). Calibration mode
times out after four minutes.
3. Close the cover, and test operation:
1 flash = increase sensitivity.
2 flashes = sensitivity correct.
3 flashes = decrease sensitivity.
4. If sensitivity needs to be adjusted, open the
cover and turn SENS clockwise to increase
sensitivity, or anticlockwise to decrease
sensitivity.
Note: Pressing and releasing the tamper
switch five times deactivates calibration mode
(indicated by a single long flash of the LED).
EN 50131-2-6,5.2,c)
The following table shows the removal\
approach distance between sensor and
magnet to activate\deactivate the alarm
state. Movement in only the axis specified
is assumed, with the sensor and magnet
positioned optimally in the other two axes.
Fe
Surface
X
Y
Z
Fe
Distance (mm)
State
22
17
15
11
14
11
14
10
32
26
19
10
Specifications
Battery: 3Vdc CR2 Lithium; low battery
warning 2.4Vdc. Typical life 1.5 years.
Current: 20µA quiescent; 25mA max.
Radio: 868.6625MHz; 10mW narrow band.
Radio range: up to 600m in free space.
Humidity: 0-95%.
Operating temp: -10 to +55°C.
Sensor dimensions (HxWxD): 103 x 19 x
24mm.
Magnet dimensions (HxWxD): 55 x 12 x 12mm.
Sensor weight: 40g (inc. battery).
Magnet weight: 10g.
Security grade: Grade 2.
Environmental: Class II.
Intrusion standards: EN 50131-2-6:2008;
EN 50131-2-8:2016; EN 50131-5-3:2017;
PD 6662:2017.
SIMPLIFIED EU DECLARATION OF
CONFORMITY
Hereby, Eaton Electrical Products Ltd
declares that the radio equipment type
DET-RSDC is in compliance with Directive
2014/53/EU. The full text of the EU
declaration of conformity is available at the
following internet address:
www.touchpoint-online.com
The information, recommendations, descriptions and
safety notations in this document are based on Eaton
Corporation’s (“Eaton”) experience and judgment and
may not cover all contingencies. If further information is
required, an Eaton sales office should be consulted. Sale
of the product shown in this literature is subject to the
terms and conditions outlined in appropriate Eaton selling
policies or other contractual agreement between Eaton
and the purchaser.
THERE ARE NO UNDERSTANDINGS, AGREEMENTS,
WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING
WARRANTIES OF FITNESS FOR A PARTICULAR
PURPOSE OR MERCHANTABILITY, OTHER THAN THOSE
SPECIFICALLY SET OUT IN ANY EXISTING CONTRACT
BETWEEN THE PARTIES. ANY SUCH CONTRACT STATES
THE ENTIRE OBLIGATION OF EATON. THE CONTENTS
OF THIS DOCUMENT SHALL NOT BECOME PART OF OR
MODIFY ANY CONTRACT BETWEEN THE PARTIES.
In no event will Eaton be responsible to the purchaser
or user in contract, in tort (including negligence), strict
liability or other-wise for any special, indirect, incidental or
consequential damage or loss whatsoever, including but
not limited to damage or loss of use of equipment, plant
or power system, cost of capital, loss of power, additional
expenses in the use of existing power facilities, or claims
against the purchaser or user by its customers resulting
from the use of the information, recommendations and
descriptions contained herein. The information contained
in this manual is subject to change without notice.
© 2020 Eaton
Eaton, Security House, Vantage Point Business Village,
Mitcheldean, GL17 0SZ.
www.touchpoint-online.com
Product Support (UK) Tel: +44 (0) 1594 541978 available
08:30 to 17:00 Monday to Friday.
email: [email protected]
Summary of Contents for DET-RSDC
Page 7: ...Page 7 ...