Introduction
The 9066 SCB bell module is designed to replace most of the current standard bell
modules in external bells/sounders. The on-board battery supplies all the current required
to drive a bell/sounder and strobe. When the sounder is not working, the control panel
trickle charges the module's battery.
The 9066 contains an internal timer that switches off the output after 20 minutes (in line
with current UK insurance requirements). The timer can be disabled by cutting link LK1
on the pcb. The pcb provides test pins that allow you shorten the timer to 15 seconds for
testing.
As supplied from the factory:
°
The trigger input is -ve removed. The module can be converted to -ve applied trigger
by cutting link LK2 on the pcb.
°
The tamper return is -ve. This can be converted to +ve tamper return by cutting link
LK3 on the pcb.
Installation Instructions
Figure 1. 9066 SCB Bell Module
Specification
Dimensions
w = 110mm, h = 50mm, d = 27mm (Pcb ONLY, incl. battery)
Battery:
7.2 volt DEAC @ 280 mAH
Quiescent Current:
30mA (battery charged ), 45mA (battery charging)
Max Output Current:
500mA (approx) @ 7.2 volts
Built-in Duration timer: 20
±
4 minutes
Wired inputs for:
Tamp - Closed circuit Enclosure Tamper switch,
Trig - Trigger, link selectable -ve Applied or Removed.
Wired Outputs for:
O/P +ve/-ve - output to Sounder/Strobe
Tamp Ret - Tamper Return, link selectable -ve or + ve return.
496210 Issue 2
Scantronic Limited Perivale Industrial Park, Greenford, Middlesex UB6 7RJ
Trig
1234
1234
1234
1234
1234
1234
1234
1234
1234
1234
1234
1234
1234
12345
12345
12345
12345
12345
12345
12345
12345
12345
12345
12345
12345
12345
12345
20 min
7.2 volt 280 mA
DEAC battery
Test
- Hold
Batt -ve
Tamp Ret
Trig
Tamp
+ Hold
- ve
+ ve
O/P
IC1
Cut for Continuous operation (Untimed)
Cut for + ve Tamper Return
Cut for - ve APPLIED trigger input
Power On LED
Tamp Ret
IC2
LK1
LK3
LK2