2.3.5 Dip Switch 

 

SW1

SW2 SW3 SW4 Mode 

ON 

OFF OFF OFF Touch Screen Calibrate mode 

OFF

ON OFF OFF Reserve 

OFF

OFF ON 

OFF Boot Loader mode 

OFF

OFF OFF ON Reserve 

OFF

OFF OFF OFF Normal 

 

 

 

 

 

z

 

Touch Screen Calibrate and Reset Password mode: In 

this mode when you power on the MT-8000/6000, the 

screen will display a “+” sign at the center of the screen. 

Use a stylus or finger to push the center of the “+” until 

it moves. The “+” moves to upper-left, upper-right, 

lower -left, lower-right and center. When all five “+” are 

done the “+” will disappear. The Touch Screen 

parameter will store at Flash Rom.   

 

z

 

If losing or forgetting system passwords, users can set 

Dip Switch 1 to “ON” position, the rest of Dips remain 

on “OFF” position and then reboot 

MT-8000/6000.Under this situation, MT-8000/6000 will 

jump to Touch Adjust (Touch screen calibration) mode. 

After calibration, the pop-up window appears as the 

illustration below. Users will be inquired if restoring the 

system password to the default value. 

z

 

When “YES” is chosen, another pop-up dialog appears 

as below. Users will be confirmed again if restoring the 

system password to the default value and will be asked 

to input “YES”. Then click OK. (The default password 

is 111111. However, other passwords, including 

download and upload password, have to be reset.) 

 

Note: When the reset action is be taken, projects and saved data in the HMI will all be cleared. 

6

 

Summary of Contents for MT-8000 Series

Page 1: ...00 Series has been tested to conform to European CE requirements This means that the circuitry is designed to resist the effects of electrical noise This does not guarantee noise immunity in severe cases Proper wire routing and grounding will insure proper operation Mechanical Environment Avoid installing units in environments where severe mechanical vibration or shocks are present 2 0 Installatio...

Page 2: ...e gases vapors or dusts z The unit should not be installed where fast temperature variations and or high humidity are present This will cause condensation of water in the device z Do not install these terminals in environments where have inflammable gases 2 2 Power Connections Make sure that all local and national electrical standards are met when the installing the unit Contact your local authori...

Page 3: ...noise into a system but if necessary an earth connection should be made from the power supply return point to the central star earth point Ground conductors should be as short and as large in size as possible The conductors must always be large enough to carry the maximum short circuit current of the path being considered Ground conductors should be connected to a tree from a central star earth gr...

Page 4: ...nded as safeguards against the failure of critical components and the effects of such failures or the inadvertent errors that might be introduced if programs are changed while the equipment is in operation z The ICS 3 304 81 Safety Recommendations are reproduced by permission of the National Electrical Manufacturers Association from NEMA ICS 3 304 2 3 Communications Connections The ports as you lo...

Page 5: ... RS 232 Port Pin Symbol Com1 RS485 2w Com1 RS485 4w Com3 RS485 Com3 RS232 1 Rx Data Rx 2 Rx Data Rx 3 Tx Tx 4 Tx Tx 5 GND Signal Ground 6 Data Data 7 TxD Transmit 8 RxD Receive 9 Data Data 2 3 3 USB Host port 5 Support various devices with USB interface such as mouse keyboard USB stick printer etc 2 3 4 Connecter Wire MT8 Ethernet RZC045120 Direct connect Ethernet crossover cable MT 8000 6000 Ethe...

Page 6: ...re at Flash Rom z If losing or forgetting system passwords users can set Dip Switch 1 to ON position the rest of Dips remain on OFF position and then reboot MT 8000 6000 Under this situation MT 8000 6000 will jump to Touch Adjust Touch screen calibration mode After calibration the pop up window appears as the illustration below Users will be inquired if restoring the system password to the default...

Page 7: ...lass A Radiated Emissions levels EN50081 2 Generic emission standard industrial environment Also US FCC Class A EN50082 2 Generic immunity standard industrial environment 3 0 Specifications MT6070T MT8070T Hardware Specification Display 7 TFT LCD Brightness 350 cd m2 Color 65 536 colors Contrast Ratio 200 1 Resolution WxH dots 480 x 234 Back light LED CCFL life time avg 30 000 hr min Touch panel 4...

Page 8: ...wiring current leakage from machine platform and incorrect input power c if the product has been maintained in a manner not conforming to product s instructions or has been modified in any way d if the serial number has been defaced or removed 4 0 Dimensions of MT 6070T MT 8070T Cutout dimensions MT 8070T 192mm 7 559 W x 138mm 5 433 H Bottom View a DIP SW Reset button e USB Host x 2 b Fuse f Com1 ...

Reviews: