9.3 Table / diagnosics data
9.3.1 Position 1 - Analogue output status
Press On-button once from position D:i – 0:0
D:i – 0:1 is displayed
As to determine the current status for all analogue outputs. Lever/joystick assignments and ana-
logue output start, stopp and ramp values.
While in this position, actuating a specific lever will result in the LED-display presenting which
output that is assigned, the direction and the current real time value.
In example:
Lever is actuated, display responds by indicating related output for 1 second
In example
1:A, 2:A, 3:A, 4:A, 5:A, 6:A, 7:A, 8:A, 1:b, 2:b, 3:b, 4:b, 5:b, 6:b, 7:b, 8:b
Followed by the current value in correspondance to lever angle.
1-99, h:i*
*h:i indicating that 100% velocity is achieved
Position / LED Indication Meaning
D:i - 0:0
Default position
D:i - 0:1
Analogue output status
D:i - 0:2
Digital output status
D:i - 0:3
Digital Input status
D:i - 0:4
Error code Log
D:i - 0:5
Program save
D:i - 0:6
Program load
D:i - 0:7
Central Unit firmware version
D:i - 08
Portable Control Unit firmware version
-
Return to position 00