9
Function
The machine is for sucking and separating dry, non-combustible dust with an explosion limit value of
0.1mg/m
3
The switch starts the motor. Dust-laden air is then sucked through the inlet valve at high speed via the
suction hose. The air is slowed down by the cyclone and coarse dust particles are separated out, partly by
centrifugal force and partly by gravity. Air and finer particles then pass through the double filter system
where they are separated. The machine is designed for reverse air pulse filter cleaning. The separated dust
accumulates in the cyclone until the machine is switched off, when it drops through the bottom flap into the
plastic bag.
Use
Before use, the user must be trained in handling the dust extractor and the hazardous dust. Connect the plug
to an outlet with the correct voltage. The filter must be cleaned from time to time. This must be done before
changing the plastic bag. It can also be done when the work is complete or when the suction is poor.
Procedure: Cover the intake, let the machine build up vacuum for a few seconds and then quickly push
down one of the handles and release it slowly. Repeat the procedure with the other handle. Repeat the
procedures 5-10 times. If suction remains poor, the filter should be replaced. The plastic bag may only be
replaced after cleaning the filter. The plastic bag must be tied up after removal. Only use original parts.
Filter change
Risk of dust dispersion -Use of personal safety equipment Unhealthy dust can be spread during filter
change. Accordingly, the user should wear protective glasses, protective gloves, and a breathing mask
conforming to protection class FFP3.
Turn the machine off and pull the plug out of the socket.
Main filter
Loosen the clamp between the upper and lower housing. Remove the hose connection Lift out the filter
holder and place it carefully on a table. Remove all screws and then remove all (4 off) filters and place them
in a plastic bag. Insert new filters in reverse order. Tighten the screws hard. Only original filters may be
used.
Micro filter
Open the top covers on the filter tanks. Carefully lift out the filter plates from the tanks and remove the
filters and place it in a clean plastic bag. This bag must be sealed properly. Insert the new filters in reverse
order. Check the seal, when changing the filters check and change defective seals. Only original filters may
be used. See accessories.
Important! The microfilters should not be cleaned, but rather replaced once they have been used Important!
The operability of the microfilters can be reduced or even totally compromised if exposed to water.