34
Dräger Interlock 7000
Adjustable parameters
9
Adjustable parameters
Some instrument parameters may be set differently by a Dräger
Interlock service centre due to legal regulations in different countries
or individually during installation.
The descriptions of these Instructions for Use are related to the
basic version.
Table of essential adjustable parameters:
Power consumption
Maximum
<2.5 A
Stand-by
<1 mA
Switch relay for the lead for the
starter relay
<16 A, continuous
<40 A, peak
Output relay
switchable de-energized
48 V
switchable energized
24 V
Ignition lead
5 V to 48 V
Waiting time to ready for
measurement
Interlock 5000
Interlock 7000
20 °C
7 s
2 s
0 °C
15 s
<5 s
-25 °C
<60 s
<60 s
-45 °C
<115 s
110 s
Parameter
Basic version
Operation
Display of test result
Test passed
/
Test failed
Breath test volume
1.0 litre
Limit value (initial test)
0.30 ‰ or 0.20 ‰
Restart period
30 minutes
Data storage
Data storage
On
Service
Calibration interval
365 days
Possible to start engine after the end of
the service interval
Yes
Retests
Retests (whilst the vehicle is in use)
No