Maintenance
Problem
Solution
Working state LED not on
The mains plug is in serte d.
Check the programme selected.
Check fuse in the house.
Full" LED on permanently
Empty condensation container.
lf failure, check hose for condensation out-
let.
Dryer does not start
Check the start button has selected.
Check the the door has closed.
Check the programme has set.
Water is running out
Align dryer horizontally.
Clear air condenser and door seals.
Door is open by itself
Press door until it" clicks" into position.
Check the clothes is over load .
Humidity in the room is in-
crease significantly
Ventilate room adequately.
Clean the cool grille.
Ensure that the air condenser has been in
serte d.
Degree of dryness was not
reached or drying time too
long
Clean lint filter and wash condenser.
Empty container.
Check water outlet.
Dryer installation too restricted.
Clean the moisture sensors.
Use next higher drying programme or us-
ing
Timer programme .
Warning!
It you cannot deal with the fault by yourself and need help:
• Press the [On/Off] button.
• Pull out the mains plug and call the service .
Product Fiches
Model ......................................................................................... TRK 3020
Rated capacity .................................................................................... 8 kg
Dryer type ................................................................................ Condenser
Energy efficiency class ....................................................................... A++
Weighted annual energy consumption (AEc) * ................. 23
5.3
kWh/year
Automatic or non-automatic .................................................. Automatic
Energy consumption of the standard cotton program ............................
Weighted energy consump. of the st. cotton prog. at full and partial load
..................................................................................................................
Energy consumption of the standard cotton program at full load ... 1,98
kWh
Energy consumption of the standard cotton program at partial load
................................................................................................... 1.08 kWh
Power consumption of the off-mode (Po) ..................................... 0,01 W
Power consumption of the left-on mode (Pl) .................................. 0,8 W
Duration of the left-on mode ......................................................... 10 min
Program time of the standard cotton program ........................................
Weighted program time of the standard cotton program at full and par-
tial load ........................................................................................ 14
2
min
Program time of the standard cotton program at full load ......... 185 min
Program time of the standard cotton program at partial load .... 110 min
Condensation efficiency class A (most efficient) to G (least efficient) ... B
Average condensation efficiency of the standard cotton program at full
load ................................................................................................. 81 %
Average condensation efficiency of the st. cotton program at partial load
........................................................................................................ 81%
Weighted condensation efficiency for the st. cotton program at full and
partial load ...................................................................................... 81%
Sound power level for the standard cotton program at full load 69dB(A)
Remarks
* Energy consumption per year, based on 160 drying cycles of the
standard cotton programme at full and partial load, and the con-
sumption of the low-power modes. Actual energy consumption per
cycle will depend on how the appliance is used
The 'standard cotton programme' used at full and partial load is the
standard drying programme to which the information in the label
and the fiche relates, that this programme is suitable for drying nor-
mal wet cotton laundry and that it is the most efficient programme
in terms of energy consumption for cotton
Technical specifications
Dimensions, HxWxD ................................................. 845 x 595 x 622 mm
Ambient temperature ............................................................ +5°C~+35°C
Rated input power .......................................................................... 850W
Rated voltage ............................................................................ 220-240V
~
Rated frequency ................................................................................ 50Hz
Refrigerant ...................................................................................... R134a
Weight of product ............................................................................. 51kg
Rated capacity .................................................................................... 8 kg
GWP .................................................................................................. 1430
CO2 – eq ......................................................................................... 0,422T
Amount of refrigerant ....................................................................... 295g
Contains fluorinated greenhouse gases covered by the Kyoto Protocol.
Hermetically sealed.
Note!
• The rated capacity is the maximum capacity, make sure that the dry
clothes which are loaded to the appliance do not exceed the rated
capacity each time.
• Do not install the tumble dryer in a room when there is a risk of
frost occurring. At temperatures around freezing point the tumble
dryer may not be able to operate properly.
• There is a risk of damage if the condensate water is allowed to
freeze in the pump, hoses and / or condensate water container.