Scales USA ACS001AC User Manual Download Page 11

SCALES usa © 2005

Page

11 of 16

The "

TARE

" indicator will be on. As product is added only the weight of 

the product will be shown. The scale could be tarred a second time if 
another type of product was to be added to the first one. Again only the 
weight that is added after tarring will be displayed.

When the container is removed, a negative value will be shown. If the 
scale was tarred just before removing the container this value is the 
gross weight of the container plus all product that was removed. The 
zero indicator will also be on because the platform is back to the same 
condition it was when the 

ZERO 

key was last pressed.

Press the 

TARE 

key again to remove the tare weight.

PRETARE:

This method allows you to enter a known value for the container weight 
from the keypad. This is useful if all containers weigh the same, or if 
the container is already full but the net weight is required and the tare 
weight of the container is known.

Remove all weight from the platform, and press the 

ZERO 

key to zero 

the display.

Enter the value for the Pretare weight

IN GRAMS!

 including decimal 

values (50.00).  Using the keypad, press

Tare

to store the tare value. 

The weight will show a negative value equal to the tare.

Note:

 If you have the scale set to operate in a unit other than grams, 

the weight will be converted to that unit in the top window, but the 
Pretare weight can only be entered in grams.

Place the container on the platform. The display will then show the 
weight of the container minus the tare weight. Then when a full 
container is placed on the platform the tare value will be subtracted 
from the gross weight displaying only the net weight of the contents.

PARTS COUNTING

SETTING UNIT WEIGHT

In order to count parts, it is necessary to know the average piece weight of 
the items to be counted. This can be done by placing a known number of the 
items on the weighing platform and letting the scale determine the average 
unit weight (Sampling), or by manually entering a known weight using the 
keypad.

WEIGHING A SAMPLE TO DETERMINE THE UNIT WEIGHT

To determine the average weight of the items to be counted it will be 
necessary to place a known quantity of the items on the scale and then 
key in the number of items being weighed. The scale will then divide 

Summary of Contents for ACS001AC

Page 1: ...SCALES usa 2005 Page 1 of 16 ACS Series Digital Counting Scales USER MANUAL...

Page 2: ...SCALES usa 2005 Page 2 of 16...

Page 3: ...cities up to 60lb 30 kg They all have stainless steel weighing platforms on an ABS base assembly All the keypads are sealed membrane switches and the displays are large easy to read liquid crystal typ...

Page 4: ...e 1 7 2 KEYBOARD 8 Figure 2 8 SCALE OPERATION 9 Power on 9 Figure 3 9 Figure 4 9 ZEROING THE DISPLAY 10 TARING 10 NORMAL TARE 10 PRETARE 11 PARTS COUNTING 11 SETTING UNIT WEIGHT 11 WEIGHING A SAMPLE T...

Page 5: ...of Measure kg g lb oz kg g lb oz kg g lb oz kg g lb oz kg g lb oz Recommended Calibrationtion Weight 1KG 2KG or 3KG 5KG 10KG 20KG Common Specifications Interface RS 232 Output NA Stabilization Time 2...

Page 6: ...s The ACS A C Series comes with a stainless steel platform packed separately Place the platform in the locating holes on the top of the scale Do not press with excessive force as this could damage the...

Page 7: ...ed STABLE The symbol appears when the reading is stable LOS The Lack of Sample symbol appears when the sample number on the platform is not enough for accurate counting operation LPW The Lack of Piece...

Page 8: ...ls the total accumulated weight and count from the memory UNIT WEIGHT CANCEL Used to enter the known unit weight In the setup mode this key is used as a cancel and exit key SAMPLE BACK LIGHT Used to i...

Page 9: ...an be used as shift key CE Used to clear the displayed numeric readings SCALE OPERATION Power on Place the scale horizontally by adjust four leveling feet at the bottom of the scale to place the bubbl...

Page 10: ...key at any time to set the zero point from which all other weighing and counting is measured It is active within 4 of power up zero This will usually only be necessary when the platform is empty When...

Page 11: ...value for the Pretare weight IN GRAMS including decimal values 50 00 Using the keypad press Tare to store the tare value The weight will show a negative value equal to the tare Note If you have the sc...

Page 12: ...ossible to enter that value using the keypad When weighing in kilograms or grams the unit weight is entered in grams When weighing in pounds the unit weight is entered in pounds When weighing in ounce...

Page 13: ...3 To observe the total stored press the TOTAL key 4 To clear the memory press TOTAL and then QUANTITY CHECK to clear all values from memory BATTERY OPERATION The scales can be operated from the intern...

Page 14: ...bility is but the slower the reaction is For example SEL 1 0 means the reaction of the scale is the quickest but its stability is the lowest SEL2 3 means the reaction of the scale is the lowest but it...

Page 15: ...he UnIt menu to enter it choose the desired unit by Shift key ZERO Press M to save it The display will show next menu Or press the UNIT WEIGHT CANCEL key to exit BK lg SELECTION OF BACKLIGHT MODE Ther...

Page 16: ...not arising out of defects in materials or workmanship During the one year warranty period if your scale fails to work properly when used under normal conditions Scales USA will repair or at our optio...

Reviews: