background image

 

5.3 Suction difficulties 

When suction difficulties appear then open the oil cap to stabilise a possible low pressure in the oil tank 
(7). The same solution can be applied with possible difficulties in retraction movement. In this case, the 
cap must be opened once the ram is correctly separated from the body. Fix the plug when the ram 
recuperates the final position. If not then too much air will remain in the oil tank. 

5.4  Oil quantity  

If the oil quantity is not correct then the maximum pressure will be overridden and this will cause 
damages when forcing the retraction of the ram. 

5.5 Flexible hose 

The flexible hose is not included with the pump. 
If the hose is replaced then it must be filled with oil once the pump is already connected. Keep the 
pump in a horizontal position at one meter below the connector head. Press the decompression valve 
and simultaneously operate to eject the residual air allowing the hose filled with oil. When the oil 
exceeds from the hose then the operation will be discontinuously and the oil level must be checked. If 
necessary add oil by following 4.2.   

 

6. GENERAL GUIDELINES 

ƒ

 

Only qualified technicians are allowed for maintenance and reparations tasks. 

ƒ

 

Using not recommended oil and tool servicing by unqualified personnel will void the warranty. 

ƒ

 

A correctly connection of the hose connector ensures a correct operation of the pump. 

 

7. TECHNICAL FEATURES 

ƒ

 

Maximum operation pressure 

700 bar 

ƒ

 

Length 700 

mm 

ƒ

 

Oil tank capacity 

1 l 

ƒ

 

Weight 12.9 

kg 

ƒ

 

3/8’’ NPT female standard connector for connecting a standard hose 

ƒ

 

Supplied with carrying case for storing the pump and the remote head 

 

8. ACCESSORIES 

Accessories supplied 

Accessories not supplied 

Carrying case 

Flexible hose 

9. GUARANTEE 

The P703F is guaranteed free of defects in material and workmanship for a period of one year from the 
date of purchase. Any defect that show up within one year will be repaired or replaced free of charge. 
As long as the tool was correctly used following the SBI’s instructions.  
After one year the units will be repaired in the factory and billed to the customer.  
Together with the unit for repair, a repair order and a short description of the failure is required.  
AII P703F pump re-constructed in the factory carry a new guarantee of six (6) months as from the date 
of leaving the factory 
 

Summary of Contents for P703F

Page 1: ...a P703F 3 2 2 Descripci n de la P703F 3 3 OPERATIVA DE FUNCIONAMIENTO 3 4 MANTENIMIENTO 4 4 1 Limpieza 4 4 2 Aceite Niveles 4 4 3 Almacenamiento 4 5 PROBLEMAS 4 5 1 Aire en el circuito hidr ulico 4 5...

Page 2: ...ta cerca de conductores con corriente puede provocar un choque el ctrico causando lesiones severas o la muerte No utilizar esta herramienta cerca de conductores con corriente sin la adecuada protecci...

Page 3: ...el pedal 2 y en su defecto el pedal 6 est listo para usarse y as el pist n de la bomba quedar preparado en su estado inicial de alimentaci n r pido y accionando el pedal ste empujar el pist n del cabe...

Page 4: ...ra en la figura Debe abrirse y retirar el tap n del dep sito de aceite Seguidamente accionar el pedal de la bomba varias veces hasta que el pist n se mueva hacia delante Despu s accionar la palanca de...

Page 5: ...racord de la manguera a la bomba para su buen funcionamiento 7 CARACTER STICAS T CNICAS M xima presi n operativa 700 bar Longitud mm 700 mm Capacidad del dep sito de aceite 1 l Peso 12 9 kg Conector r...

Page 6: ...read understand and follow these instructions and ALL safety warnings and labels before operating these tools Only use these tools in accordance with the SBI s specifications Other use of these tools...

Page 7: ...l keep all safety labels clean and legible Replace labels when necessary with new labels See the PARTS SECTION of this manual for information on reordering Safety is everyone s responsibility 2 INTROD...

Page 8: ...s The pump can be cleaned with gasoline but the guide of the ram should be regularly lubricated with grease 4 2 Oil level The oil tank capacity is 1 litter To check the oil level place the pump horizo...

Page 9: ...ed If necessary add oil by following 4 2 6 GENERAL GUIDELINES Only qualified technicians are allowed for maintenance and reparations tasks Using not recommended oil and tool servicing by unqualified p...

Page 10: ...s dans ce manuel sont essentiels la manipulation l utilisation et l entretien en toute s curit de la pompe P703F L utilisateur doit lire comprendre et suivre ces instructions et TOUTES les mises en ga...

Page 11: ...de la zone de travail et assurez des appuis s rs pour vous et votre t che TOUJOURS poser les pieds de mani re stable et garder l quilibre Utilisez tous les quipements de protection individuelle adapt...

Page 12: ...de la valve pour corriger la position du connecteur en r tractant le piston Une fois que le connecteur est dans une position correcte on peut actionner la p dale 2 de nouveau Quand la compression est...

Page 13: ...ce cas le reservoir d huile 1 doit tre ouvert jusqu ce que le piston soit s par correctement du corps Remettre le bouchon 1 lorsque le piston aura r cup r sa position finale Si ce n est pas le cas c...

Page 14: ...703F est garantie contre tout d faut de fabrication pour une p riode d un an partir de la date d achat Tout d faut qui pourrait se manifester pendant ces 12 mois sera r par la charge du fournisseur co...

Reviews: