Direction for Use

1. Operation method and steps

Check: 

 

Whether the strainer for the Intelligent & ultrasonic sink is in a state of water storage;

              Whether the intelligent driver of the sink is electrified.

Turn on the tap to inject at least 1/3 water of the sink; for the specific amount of water, it 

depends on the number of items to be cleaned.

Please do not start the Intelligent 
& ultrasonic sink when there is no 
water in it.

1/3

Note: For dirt that is difficult to remove, please dip it for a 
while before cleaning to achieve a better effect; or, you can 
put it in warm water.

Figure (8) Minimum Water Level Requirement and Suggestions

Put items to be cleaned in the Intelligent & ultrasonic sink ,  and the objects should be in 

contact with water; please do not stack them, as stacking may affect the cleaning effect.

Start the Intelligent & ultrasonic sink by an operation panel.

The layout of the operation panel is shown in Figure (9) below.

Indication

Power

Indication

Seafood

Indication

Fruits & vegetables

Indication

Cutlery

Indication

MEAT

Touch-

sensing

Power

Touch-

sensing

Seafood

Touch-

sensing

Fruits & vegetables

Touch-

sensing

Cutlery

Touch-

sensing

MEAT

Indication area: 
If the light of an indication 
area goes on, it indicates 
t h a t t h e c o r r e s p o n d i n g 
function button has been 
initiated

Touch-screen area: 
It is for touch control and 
initiating the corresponding 
function button

Figure (9) Schematic Diagram of Operation Panel

How to use the Intelligent & ultrasonic sink funtion through the operation panel? 

Refer Figure (10).

1) Turn on "Power": Keep pressing the "Power" sensing position for 1 second to turn on the 

    power, and the light of the "Power" indication area on the operation panel is on.

2) To start a function : After the light of the "Power" indication area is on, touch a function 

     

button according to the object to be cleaned, and the corresponding indication area lights 

     

up; in this case, other function buttons in addition to the "Power" button are locked and have 

     

no response to any touch, and the cleaning starts.

3) Stop Cleaning: If you need to stop the cleaning in this process, please touch the corresponding 

    function button again so that the corresponding indication area darkens and the cleaning 

    is discontinued. After one minute, the sink will be shut off automatically.

1) Turn on "Power"

4) End of cleaning: After the completion of cleaning, the corresponding indication area 

     

automatically darkens, and you can touch the "Power" button to power off; or, wait for 1 

     

minute until the sink’s power is shut off automatically.

2) To start a function

3) Stop Cleaning

4) End of cleaning

Cautions

In order to protect you and your family from being injured or financial losses, please 

read the following details carefully before using the water tank, to ensure correct and 

safe operation.

Power socket of intelligent & ultrasonic sink must be reliably grounded.

Only the voltage indicated on the apparatus is applicable to the intelligent & ultrasonic sink, 

and please makes sure that the voltage conforms to relevant safety standards.

Summary of Contents for Innova DBC Series

Page 1: ...MANUAL AYO ULTRASONIC KITCHEN SINK ...

Page 2: ...different numbers of items at different water levels without any residual at a vibration frequency of 30 000 40 000Hz Product Features Product Characteristics Environment friendly Only water is needed free of any chemical substances cleaner Cleaner Cleaning deeply to effectively remove pesticides germs and grease etc Intelligent Based on a microcomputer intelligent control system multiple modes ar...

Page 3: ...iver Tapemeasure Drilling saw or saber toothed saw Pencil Gloves Drill Jigsaw Innova DBC Innova DBC Product Specification Model Rated Power Voltage Dimension mm Template cutting size mm 350W 350W 220V 50HZ 220V 50HZ 850x460 520x460 820x430 490x430 Installation Instruction 1 Hole cut out Mark it out in a position with a proper distance from the cabinet by referring to technical parameters in this m...

Page 4: ...n screwed to be fixed Note the spacer should be above the table Pull the drawing pin 002 back to a catching groove as shown in Figure 4 1 and embed the steel wire ball head 001 into the steel wire groove as shown in Figure 4 2 and finally pull back drawing pin 002 and fasten the steel wire as shown in Figure 4 3 Press the switch installed down to extend the steel wire from one end Install the drai...

Page 5: ...ether the sink drains smoothly Adjust the adjusting screw 003 with reference to Figure 4 according to the observation 6 Sink Fixation After the completion of testing waterproof glue is applied around the edges of the sink to fix it and prevent water seepage on the table Fix the intelligent driver on and inside the cabinet and at least 10cm away from the bottom of the cabinet After installation it ...

Page 6: ...agram of Operation Panel How to use the Intelligent ultrasonic sink funtion through the operation panel Refer Figure 10 1 Turn on Power Keep pressing the Power sensing position for 1 second to turn on the power and the light of the Power indication area on the operation panel is on 2 To start a function After the light of the Power indication area is on touch a function button according to the obj...

Page 7: ...the sink instead use soft household sponge or cloth 4 Drying is very important to eliminate the collection of lime scale mineral deposits and calcium stake 5 Always rinse the sink after every use and wipe dry 6 Avoid prolonged contact with citric or high salt concentration food as it can lead to staining pitting and corrosion of the sink 7 Prolonged exposure to direct sunlight will lead the film c...

Page 8: ...12 ...

Reviews: