background image

You have correctly identified the wires.
The connections are tight.
No loose strands have been left out of the connection block.

Installation

Wiring

Check That

Commissioning

Existing fittings must be completely removed before installation of a new product. Before removing the existing 
fitting, carefully note the position of each set of wires.
1.  Undo the four screws covering the terminal block and remove.
2.  Mark the mounting hole positions onto the wall. Drill and plug the wall at the marked positions. Ensure the 

wall is capable of holding the weight of the product. Take care to avoid damaging any concealed wiring and pipes. 
The correct fixings should be used for brick or cavity walls. Fix to the wall

3.  Undo the screws holding the cable clamp and set aside. Pull the cable through the gland.
4.  Wire the product as detailed below.

Cable Clamp

Gland

Wall Bracket

PIR Screw

Terminal Box
Cover Screws

Shade Screw

Having correctly identified the wiring from your existing light fitting, pull the wire through the hole and connect to 
the connection block inside the product in the following way:

Check that.....
 You have correctly identified the wires.
 The connections are tight.
 No loose strands have been left out of the connection 
block.

5. 

Pull the cable through the gland, and secure the supply cable under the clamp. Tighten the gland.

6. 

Refit the terminal block cover using the four screws.

7. 

Replace fuse or circuit breaker and switch on. Your light is now ready for use. 

NEUTRAL

EARTH (GREEN/YELLOW ) 

LIVE

BLUE (N)

INTERNAL WIRE (BLACK)

GREEN/YELLOW

BROWN (L)

SUPPLY

LIGHT FITTING

INTERNAL CABLE (WHITE)

When changing a bulb, always switch off at the mains and allow the bulb to cool before 
handling. Dispose of used bulbs carefully. Use a soft cloth to handle bulbs, avoid directly 
touching the bulbs as this will shorten their life.
Do not exceed the wattage stated or use a different shape bulb from that indicated on 
the fitting.
Undo the screw on the top of the shade to access the bulb.

Fitting / Replacing Bulbs 

400W MAX R7S 117mm

Reviews: