We recommend cleaning with a soft dry cloth.
Do not use solvents or abrasive cleaners as these could damage the finish.
Glass parts -  Clean using a damp cloth. Do not use abrasive materials as these will damage the finish.
Do not clean the units with a pressure washer.

Waste electrical products should not be disposed of with household waste. Please recycle where 
facilities exist. Check with your Local Authority or retailer for recycling advice.

For your safety, always switch off the supply before changing lightbulbs, or cleaning.
This system contains non-replaceable parts and cannot be serviced. If damage occurs the part should be scrapped.

Saxby Lighting Ltd. BH23 3PE

Care and Cleaning 

Recycling Advice 

Safety Information 

The shade must be replaced immediately should the shade become cracked or damaged. This 
fitting must not be used without the shade in place.

Replace Cracked

Shade

2.5 Meters 

8M 

4M 

12M 

approx.110 deg 

SENS

TIME

LUX

PIR Operation

1. 

The detection area of the PIR is as shown in the top diagram.

2. 

Adjusting the Time: The length of time that the fitting remains switched 
on after activation can be adjusted from 10 (±5) seconds to 4 (±1) 
minutes. Rotating the Time knob from (+) to (-) will reduce the 
duration time. 

 

Note: Once the light has been triggered by the PIR sensor any 
subsequent detection will start the timed period again from the 
beginning.

3. 

Adjusting the Daylight Control Level: The Daylight control module has 
a built in sensing device (photocell) that detects daylight and darkness. 
Rotate the Daylight knob dockwise is from light (sun) to dark (moon). 
The (sun) position denotes that the floodlight can work at day and 
night. and the (moon) position only works at night. You can set to 
operate the unit at the desired level by adjusting the Daylight knob .

4. 

Put the Daylight control knob to light (sun) position. turn the wall 
switch on and wait 30 seconds for the control circuit to stabilize.

 

At this stage ensure that the TIME control knob is set at minimum 
duration time (-) position (Rotating the Time knob clockwise to the 
stop-position). The floodlight will now switch on and remain on for 
about 30 seconds (within 60 seconds).

5. 

Direct the sensor toward the desired area to be scanned by adjusting 
the swivel joint on the sensor arm,

 

Important: loosen the lock nuts and screws on the sensor and 
floodlight before making any adjustments.

6. 

Have another person move across the center of the area to be scanned and slowly adjust the angle of the 
sensor arm until the unit senses the presence of the moving person, causing the flood light to switch on.

7. 

Adjust time control to required setting.

8. 

To set the light level at which the floodlight will automatically switch ‘on’ at night, turn the Daylight control 
knob from daylight (sun) to night (moon). If the floodlight is required to switch on earlier, e.g. dusk, wait for 
the desired light level then slowly turn the Daylight control knob towards daylight while someone walks 
across the center of the area to be detected. When the floodlight switches on release the Daylight control 
knob. You may need to make further adjustments to achieve your ideal light level setting.