Prepared by Sally

Lamp turns 
ON at night.

Lamp turns ON

at day & night. 

The purpose of the lens mask is to mask out areas not desired for detection.

Masking The Sensor Lens:

Lens masking

Setting Advise

WARNING

•  To restrict the sensor coverage, preventing detection in unwanted areas, 

mask the sensor lens using the masking label provided. The top section of 

the lens covers long range detection, the bottom covers short range. 

Similarly the left and right lens sections cover the left and right detection 

areas respectively.

 Lamp Adjustment

-20

+40

10

20

30

40

50

60

This product will get warm when in 

normal use.  Can be installed on 

surfaces of normal flammability 

e.g. wood, plasterboard, brickwork 

and other masonry.  Do not install 

on flammable surfaces such as 

plastics.

Note:

A proof of purchase is required in all cases. For all eligible replacements 

(where agreed by Timeguard) the customer is responsible for all 

shipping/postage charges outside of the UK. All shipping costs are to be 

paid in advance before a replacement is sent.

WARNING

TG-LED-X30W PIR-D-B - N1  

3 Year Guarantee

In the unlikely event of this product becoming faulty due 
to defective material or manufacture within 3 years of the
date of purchase, please return it to your supplier in the
first year with proof of purchase and it will be replaced free 
of charge. For years 2 and 3 or any difficulty in the first year telephone
the helpline on 020 8450 0515. 

 30W LED PIR 

FLOODLIGHT

Model: LEDX30PIRB

Model: LEDX30PIRWH 

 67.058.503 (Iss.2)

020 8450 0515

 

 

Knob Settings

LEDX30PIR has two adjustment knobs: 

Time and Lux at the bottom of the detector head.
•  Adjust knobs carefully with flat blade screwdriver.

TIME knob setting

•  You can set the time knob from 5 sec to about 10 min, LEDX30PIR will 

   turn ON the lamp, for the time duration set after each detected movement.
•  Adjust the knob as desired.

LUX knob setting

•  When setting the Lux knob at “MOON”, LEDX30PIR will only operate

   in the dark. 

 

•  When setting the Lux knob at “SUN”, LEDX30PIR  will operate in any 

   light level.

Dusk Setting (Time knob setting)

•  When setting the Time knob to fully clock wise, the motion detector of 

   LEDX30PIR won’t function.   

   The lamp will operate depending on the “LUX” level, ie Dusk to Dawn..

 

Tilt downward 60º

Tilt upward 45º

The lamp can be tilted upward 45º and
tilted downward 60º.
 

10min

5sec

0

Min

10

0 5

sec

Turn On time adjustment

Environment lux level to turn On

Adjustments

Dusk/Dawn

Time

Test mode

Manual Override Mode:

The light can be switched on for longer time periods by use of the Manual 

Override Mode.

This can be activated at night by using the internal wall switch or circuit 

breaker.

Switch the internal wall switch/circuit breaker single (OFF/ON) within 1 

second. 

The unit will now illuminate continuously until dawn or until switched back 

into Auto Mode. 

To switch the unit back into Auto Mode, switch the internal wall switch/circuit 

breaker once (OFF/ON) within one second. 

The unit will return to its Auto mode and will operate as set up after the walk 

test procedure.

Timeguard Limited. 

Victory Park, 400 Edgware Road, 

London NW2 6ND

Sales Offi ce: 020 8452 1112

or email csc @ timeguard.com

For a product brochure please contact:

or email helpline @ timeguard.com

HELPLINE

020 8450 0515

If you experience problems refer to Troubleshooting Guide.

If problems still exist, do not immediately return the unit to store.

Telephone the Timeguard Customer Helpline

Qualified Customer Support Co-ordinators will be on-line to assist

in resolving your query. 

Technical specifications:

 

 

Max. 10 sets

Max. 10 sets with total 200W

Max. 1000W 

Max. 15 sets 23W or Max. 345W

Max. 648W 

LEDX30FL

LED lamp 

Halogen lamp 

CFL

Fluorescent tube w/o PF correction  

Slave Output:

Energy Usage Lamp On

Power Supply

Power Factor

Colour Temperature 

Colour Rendering

Lumen Output initial

Detection Range

Detection Angle

 

Lamp Beam Angle

 

Time On Adjustment

 

Dusk Level Adjustment

 

Environmental Protection

EC Directives

 

Energy Efficiency

Class A+

28kWh/1000h: 27.5W typ

230 V AC ~ 50Hz 

 > 0.95 

5000 - 5600K

> 70

Black: 2115 Im typ, White: 2310 lm typ

Up to 12 metres

180º

110 x 100 degrees

The lamps are not replaceable in this product

5 seconds - 10 minutes

Day & night or night only operation

IP55 (suitable for indoor and outdoor use)

Conforms to  current EC Directives

Summary of Contents for LEDX30PIRB

Page 1: ...30W LED PIR FLOODLIGHT Model LEDX30PIRB Model LEDX30PIRWH ...

Page 2: ...dure Page 4 Installation procedure Page 5 Sensor detection range Page 6 Walk test adjustment Detector head adjustment Page 7 Knob settings Page 8 Lens masking Page 9 Lamp adjustment and Warning Page 10 Technical Specifications 2 Basic Safety Instruction Danger of death through electric shock Must only be installed by qualified electricians Avoid the metal parts of the device due to potentially high...

Page 3: ...d Tools Equipment need for installation INSTRUCTIONS MANUAL X1 X1 X1 X2 X2 X1 Screw M4x32mm Screw peg 6x30mm X2 X4 Screw M3x12mm X 1 X 1 X 1 Flat blade screw driver Suitable for screw head Drill bit with diameter 6mm Product s weight LEDX30PIR 1kg ...

Page 4: ...ection Switch off the electricity at the fuse box by removing the relevant fuse or switching off the circuit breaker before proceeding with the installation IMPORTANT 2 3 1 230V 4 Mounting Screws M4 x 32 x 2 φ 6mm Fix the U bracket to the wall Switch off the power Drill and push the screw peg into the hole Marking the screw hole 6 Installation Procedure Mains Supply N E L Isolation Switch Load Max...

Page 5: ...of the junction box 9 11 Attach the strain relief to the device and screw in Tighten the screws 6 7 Attach the device to the U bracket then tighten the screws on both sides EARTH LIVE NEUTRAL EARTH BLUE GREEN YELLOW BROWN LIVE NEUTRAL EARTH BLUE GREEN YELLOW BROWN Connect the mains supply cable to the terminal block on the backplate as follows See connection diagram CONNECTION click Push Connect t...

Page 6: ...e of about 180 deg 180 up to12m 3m 1 80 2 5 METER 1 2 M E T E R 3 METER 180 Installation Advise As the detector reacts to variations in temperature avoid situations Do not install motion detectors near heat sources such as heating outlets air conditioning system lamps etc Do not direct the motion detector at objects that move in the wind such as curtains large plants etc Take account of motion dir...

Page 7: ...test procedure Test procedure Adjust the Time knob to fully anti clockwise Lux knob can be Sun or Moon Walk across the detection area once the detector is triggered and the lamp will turn ON for 2 seconds Note walking direction when performing test Do not use the adjuster knobs to turn the detector head 0 2 Sec 2 sec Dusk Time Test mode Tilt down 90º Pan left 90º Pan right 90º The detector head ca...

Page 8: ...t Adjust the knob as desired LUX knob setting When setting the Lux knob at MOON LEDX30PIR will only operate in the dark When setting the Lux knob at SUN LEDX30PIR will operate in any light level Dusk Setting Time knob setting When setting the Time knob to fully clock wise the motion detector of LEDX30PIR won t function The lamp will operate depending on the LUX level ie Dusk to Dawn 10min 5sec 0 M...

Page 9: ...Lens Lens masking Setting Advise WARNING To restrict the sensor coverage preventing detection in unwanted areas mask the sensor lens using the masking label provided The top section of the lens covers long range detection the bottom covers short range Similarly the left and right lens sections cover the left and right detection areas respectively ...

Page 10: ...e Mode The light can be switched on for longer time periods by use of the Manual Override Mode This can be activated at night by using the internal wall switch or circuit breaker Switch the internal wall switch circuit breaker single OFF ON within 1 second The unit will now illuminate continuously until dawn or until switched back into Auto Mode To switch the unit back into Auto Mode switch the in...

Page 11: ...mmediately return the unit to store Telephone the Timeguard Customer Helpline Qualified Customer Support Co ordinators will be on line to assist in resolving your query Technical specifications Max 10 sets Max 10 sets with total 200W Max 1000W Max 15 sets 23W or Max 345W Max 648W LEDX30FL LED lamp Halogen lamp CFL Fluorescent tube w o PF correction Slave Output Energy Usage Lamp On Power Supply Pow...

Page 12: ...ss 2 Timeguard Limited Victory Park 400 Edgware Road London NW2 6ND Sales Office 020 8452 1112 or email csc timeguard com For a product brochure please contact or email helpline timeguard com HELPLINE 020 8450 0515 ...

Reviews: