background image

LEDX30PIRB.1  Instructs_147x105-R2a   1-6

27-01-14  9.30AM

Prepared by Sally

1

2

3

4

5

6

 (FRONT)

1. Designated Use

•  LEDX30PIR is an outdoor motion detector for automatic LED lighting 

   control.
•  Mainly for wall installation.
•  Simple plug in wall plate for easy & safe connection
•  Suitable for a wide range of locations: corridors, gardens, staircases, 
  entrances, garages, outdoor parking areas etc.

Index :

Page 2 

Contents and Tools required

Page 3 

Connection and Installation procedure

Page 4 

Installation procedure

Page 5 

Sensor detection range

Page 6 

Walk test & adjustment, Detector head adjustment

Page 7 

Knob settings

Page 8 

Lens masking

Page 9 

Lamp adjustment and Warning

Page 10  Technical Specifications

18

0

1.

TO

 2.

ME

TE

R

12 ME

TER

3 METER

18

0

1.8 

TO

 2.5 

M

E

TER

12 ME

TER

3 METER

18

0

1.

TO

 2

.5 M

E

TE

R

12 ME

TER

3 METER

10

20

30

40

40

10

20

30

40

40

10

20

30

40

40

Detection Range:

LEDX30PIR:

Recommended installation height is 2.5 meter above

ground, the maximum detection range about 12 meter and at the angle 

of about 180 deg.

180°

up to12m

3m

18

0

2.5 M

E

TE

R

12 ME

TER

3 METER

180°

 

•  Switch power on.

Detector Head Adjustment

Walk Test and Adjustment

The purpose of Walk Test is used to test and adjust the detection coverage of 

LEDX30PIR under auto mode.

•  Adjust the Time knob to minimum (fully anti-clockwise), then conduct a 

   walk test as described in test procedure. 

Test procedure:

•  Adjust the Time knob to  (fully anti-clockwise), (Lux knob can be “Sun” or

   “Moon”).

•  Walk across the detection area, once the detector is triggered and the lamp 
  will turn ON for 2 seconds.

Note walking direction when performing test.

* Do not use the adjuster knobs to turn 

the detector head.

0

2

Sec

2 sec

Dusk

Time

Test mode

Tilt down 90º

Pan left 90º

Pan right 90º

The detector head can be 90º turned left or right by hand and can be tilted 
90º downward .

Installation Advise:

As the detector reacts to variations in temperature, avoid situations:

• Do not install motion detectors near heat sources such as heating outlets,

  air conditioning system, lamps etc.
• Do not direct the motion detector at objects that move in the wind such 

   as curtains, large plants etc. 
• Take account of motion direction during test run.

WARNING

• Do not direct motion detectors at objects with highly-reflective surface 

   such as mirrors etc.

2. Basic Safety Instruction

Danger of death through electric shock.
•  Must only be installed by qualifi ed electricians.
•  Avoid the metal parts of the device due to potentially high temperature.

•  Designed for use in normal environments
•  Intended for outdoor installation.
•  Energy saving.
•  Long LED lamp life time.

WARNING

•  Conforms to the latest EC directives. 
 

3. Contents:

   What’s in the box?

4. Tools required:

Tools / Equipment need for installation. 

INSTRUCTIONS

MANUAL

X 1

X 1

X 1

X 2

X 2

X 1

Screw:

 M4x32mm   

Screw peg: 

6x30mm

X 2

X 4

Screw:

 M3x12mm   

X 1

X 1

X 1

Flat blade screw driver

Suitable for screw head

Drill bit with diameter 6mm

LIVE

BROWN

LIVE

NEUTRAL

EARTH

BLUE

GREEN / YELLOW

BROWN

Screw: M3x12mm x 4  

Product’s weight:
LEDX30PIR : 1kg

Connect the cable to the terminal block as follows (see connection diagram):
Ensure the connections are secure. Refit wall plate ensuring it clicks

firmly into place.

5. Connection:

Master-Slave connection

Switch off the electricity at the fuse box by removing the relevant fuse or 

switching off the circuit breaker before proceeding with the installation.

*** IMPORTANT ***

2

5

3

1

230V

4

Mounting  Screws: (M4 x 32) x 2

φ 6mm

Fix the U bracket to the wall.

Switch off the power.

Drill and push the screw 

peg into the hole.

Connect device

to the mains.

Unit goes into   

warm-up period 

for 40 sec.

10

Loosen the screws.

Attach the 

wallplate 

to the device.

Marking the screw hole.

12

8

Connect the individual wires to the appropriate terminal then tighten

the screws.

First, feed the cable through the 

rubber gasket of the junction box.

9

11

Attach the strain relief to the 

device and screw in.

Tighten the screws.

6

7

Attach the device to the U 

bracket then tighten the 

screws on both sides.

EARTH

LIVE

NEUTRAL

EARTH

BLUE

GREEN / YELLOW

BROWN

LIVE

NEUTRAL

EARTH

BLUE

GREEN / YELLOW

BROWN

Connect the mains supply cable to the

 terminal block on the backplate as follows.

( See connection diagram )

CONNECTION

“click”

Push

Connect the cable from the lighting load to the 

terminal block on the backplate as follows. 

6. Installation Procedure:

Mains 

Supply

N

E

L

 Isolation Switch

Load

Max. wire

1 x 2.5mm per way

Max. wire

2 x 1.5mm per way

Summary of Contents for LEDX30PIRB

Page 1: ...30W LED PIR FLOODLIGHT Model LEDX30PIRB Model LEDX30PIRWH ...

Page 2: ...dure Page 4 Installation procedure Page 5 Sensor detection range Page 6 Walk test adjustment Detector head adjustment Page 7 Knob settings Page 8 Lens masking Page 9 Lamp adjustment and Warning Page 10 Technical Specifications 2 Basic Safety Instruction Danger of death through electric shock Must only be installed by qualified electricians Avoid the metal parts of the device due to potentially high...

Page 3: ...d Tools Equipment need for installation INSTRUCTIONS MANUAL X1 X1 X1 X2 X2 X1 Screw M4x32mm Screw peg 6x30mm X2 X4 Screw M3x12mm X 1 X 1 X 1 Flat blade screw driver Suitable for screw head Drill bit with diameter 6mm Product s weight LEDX30PIR 1kg ...

Page 4: ...ection Switch off the electricity at the fuse box by removing the relevant fuse or switching off the circuit breaker before proceeding with the installation IMPORTANT 2 3 1 230V 4 Mounting Screws M4 x 32 x 2 φ 6mm Fix the U bracket to the wall Switch off the power Drill and push the screw peg into the hole Marking the screw hole 6 Installation Procedure Mains Supply N E L Isolation Switch Load Max...

Page 5: ...of the junction box 9 11 Attach the strain relief to the device and screw in Tighten the screws 6 7 Attach the device to the U bracket then tighten the screws on both sides EARTH LIVE NEUTRAL EARTH BLUE GREEN YELLOW BROWN LIVE NEUTRAL EARTH BLUE GREEN YELLOW BROWN Connect the mains supply cable to the terminal block on the backplate as follows See connection diagram CONNECTION click Push Connect t...

Page 6: ...e of about 180 deg 180 up to12m 3m 1 80 2 5 METER 1 2 M E T E R 3 METER 180 Installation Advise As the detector reacts to variations in temperature avoid situations Do not install motion detectors near heat sources such as heating outlets air conditioning system lamps etc Do not direct the motion detector at objects that move in the wind such as curtains large plants etc Take account of motion dir...

Page 7: ...test procedure Test procedure Adjust the Time knob to fully anti clockwise Lux knob can be Sun or Moon Walk across the detection area once the detector is triggered and the lamp will turn ON for 2 seconds Note walking direction when performing test Do not use the adjuster knobs to turn the detector head 0 2 Sec 2 sec Dusk Time Test mode Tilt down 90º Pan left 90º Pan right 90º The detector head ca...

Page 8: ...t Adjust the knob as desired LUX knob setting When setting the Lux knob at MOON LEDX30PIR will only operate in the dark When setting the Lux knob at SUN LEDX30PIR will operate in any light level Dusk Setting Time knob setting When setting the Time knob to fully clock wise the motion detector of LEDX30PIR won t function The lamp will operate depending on the LUX level ie Dusk to Dawn 10min 5sec 0 M...

Page 9: ...Lens Lens masking Setting Advise WARNING To restrict the sensor coverage preventing detection in unwanted areas mask the sensor lens using the masking label provided The top section of the lens covers long range detection the bottom covers short range Similarly the left and right lens sections cover the left and right detection areas respectively ...

Page 10: ...e Mode The light can be switched on for longer time periods by use of the Manual Override Mode This can be activated at night by using the internal wall switch or circuit breaker Switch the internal wall switch circuit breaker single OFF ON within 1 second The unit will now illuminate continuously until dawn or until switched back into Auto Mode To switch the unit back into Auto Mode switch the in...

Page 11: ...mmediately return the unit to store Telephone the Timeguard Customer Helpline Qualified Customer Support Co ordinators will be on line to assist in resolving your query Technical specifications Max 10 sets Max 10 sets with total 200W Max 1000W Max 15 sets 23W or Max 345W Max 648W LEDX30FL LED lamp Halogen lamp CFL Fluorescent tube w o PF correction Slave Output Energy Usage Lamp On Power Supply Pow...

Page 12: ...ss 2 Timeguard Limited Victory Park 400 Edgware Road London NW2 6ND Sales Office 020 8452 1112 or email csc timeguard com For a product brochure please contact or email helpline timeguard com HELPLINE 020 8450 0515 ...

Reviews: