LEDX30PIRB.1 Instructs_147x105-R2a 1-6
27-01-14 9.30AM
Prepared by Sally
1
2
3
4
5
6
(FRONT)
1. Designated Use
• LEDX30PIR is an outdoor motion detector for automatic LED lighting
control.
• Mainly for wall installation.
• Simple plug in wall plate for easy & safe connection
• Suitable for a wide range of locations: corridors, gardens, staircases,
entrances, garages, outdoor parking areas etc.
Index :
Page 2
Contents and Tools required
Page 3
Connection and Installation procedure
Page 4
Installation procedure
Page 5
Sensor detection range
Page 6
Walk test & adjustment, Detector head adjustment
Page 7
Knob settings
Page 8
Lens masking
Page 9
Lamp adjustment and Warning
Page 10 Technical Specifications
18
0
1.
8
TO
2.
5
ME
TE
R
12 ME
TER
3 METER
18
0
1.8
TO
2.5
M
E
TER
12 ME
TER
3 METER
18
0
1.
8
TO
2
.5 M
E
TE
R
12 ME
TER
3 METER
10
20
30
40
40
10
20
30
40
40
10
20
30
40
40
Detection Range:
LEDX30PIR:
Recommended installation height is 2.5 meter above
ground, the maximum detection range about 12 meter and at the angle
of about 180 deg.
180°
up to12m
3m
18
0
2.5 M
E
TE
R
12 ME
TER
3 METER
180°
• Switch power on.
Detector Head Adjustment
Walk Test and Adjustment
The purpose of Walk Test is used to test and adjust the detection coverage of
LEDX30PIR under auto mode.
• Adjust the Time knob to minimum (fully anti-clockwise), then conduct a
walk test as described in test procedure.
Test procedure:
• Adjust the Time knob to (fully anti-clockwise), (Lux knob can be “Sun” or
“Moon”).
• Walk across the detection area, once the detector is triggered and the lamp
will turn ON for 2 seconds.
Note walking direction when performing test.
* Do not use the adjuster knobs to turn
the detector head.
0
2
Sec
2 sec
Dusk
Time
Test mode
Tilt down 90º
Pan left 90º
Pan right 90º
The detector head can be 90º turned left or right by hand and can be tilted
90º downward .
Installation Advise:
As the detector reacts to variations in temperature, avoid situations:
• Do not install motion detectors near heat sources such as heating outlets,
air conditioning system, lamps etc.
• Do not direct the motion detector at objects that move in the wind such
as curtains, large plants etc.
• Take account of motion direction during test run.
WARNING
• Do not direct motion detectors at objects with highly-reflective surface
such as mirrors etc.
2. Basic Safety Instruction
Danger of death through electric shock.
• Must only be installed by qualifi ed electricians.
• Avoid the metal parts of the device due to potentially high temperature.
• Designed for use in normal environments
• Intended for outdoor installation.
• Energy saving.
• Long LED lamp life time.
WARNING
• Conforms to the latest EC directives.
3. Contents:
What’s in the box?
4. Tools required:
Tools / Equipment need for installation.
INSTRUCTIONS
MANUAL
X 1
X 1
X 1
X 2
X 2
X 1
Screw:
M4x32mm
Screw peg:
6x30mm
X 2
X 4
Screw:
M3x12mm
X 1
X 1
X 1
Flat blade screw driver
Suitable for screw head
Drill bit with diameter 6mm
LIVE
BROWN
LIVE
NEUTRAL
EARTH
BLUE
GREEN / YELLOW
BROWN
Screw: M3x12mm x 4
Product’s weight:
LEDX30PIR : 1kg
Connect the cable to the terminal block as follows (see connection diagram):
Ensure the connections are secure. Refit wall plate ensuring it clicks
firmly into place.
5. Connection:
Master-Slave connection
Switch off the electricity at the fuse box by removing the relevant fuse or
switching off the circuit breaker before proceeding with the installation.
*** IMPORTANT ***
2
5
3
1
230V
4
Mounting Screws: (M4 x 32) x 2
φ 6mm
Fix the U bracket to the wall.
Switch off the power.
Drill and push the screw
peg into the hole.
Connect device
to the mains.
Unit goes into
warm-up period
for 40 sec.
10
Loosen the screws.
Attach the
wallplate
to the device.
Marking the screw hole.
12
8
Connect the individual wires to the appropriate terminal then tighten
the screws.
First, feed the cable through the
rubber gasket of the junction box.
9
11
Attach the strain relief to the
device and screw in.
Tighten the screws.
6
7
Attach the device to the U
bracket then tighten the
screws on both sides.
EARTH
LIVE
NEUTRAL
EARTH
BLUE
GREEN / YELLOW
BROWN
LIVE
NEUTRAL
EARTH
BLUE
GREEN / YELLOW
BROWN
Connect the mains supply cable to the
terminal block on the backplate as follows.
( See connection diagram )
CONNECTION
“click”
Push
Connect the cable from the lighting load to the
terminal block on the backplate as follows.
6. Installation Procedure:
Mains
Supply
N
E
L
Isolation Switch
Load
Max. wire
1 x 2.5mm per way
Max. wire
2 x 1.5mm per way