Thank you for purchasing this light fitting. Please read the instructions carefully before use to ensure safe and 
satisfactory operation of this product. Please retain these instructions for future reference.

Warning

This is a Class 1 product and must be earthed.

Please read these instructions carefully before 
commencing any work.

This unit must be fitted by a competent and qualified 
electrician.

Install in accordance with IEE Wiring regulations and 
current Building Regulations.

To prevent electrocution switch off at mains supply 
before installing or maintaining this fitting. Ensure 
other persons cannot  restore the electrical supply 
without your knowledge. If you are in any doubt, 
please consult a qualified electrician.

This light fitting should be connected to a circuit with a 
30mA RCD fitted.

If replacing an existing fitting, make a careful note of 
the connections.

The unit cannot be dimmed.

This system contains non-replaceable parts and 
cannot be serviced. If damage occurs the part should 
be scrapped.

Waste electrical products should not be disposed of 
with household waste. Please recycle where facilities 
exist. Check with your local authority or retailer for 
recycling advice.

This product is rated at IP65.

This  product is not suitable for location in or near a 
marine environment.

The entire unit gets hot whilst on for a period of time.

Specification

Voltage: 

240V ~ 50Hz

Lamp: 

48742 1 x 10W LED COB, 48746 : 1 x  30W LED COB, 

IP rating: 

65

Layout

•  Plan the desired layout of this fitting carefully, 

ensuring the cable has enough flex to allow for 
future tilt adjustments if necessary.

•  Avoid locating any cables in positions that would 

cause a hazard. Position cables and outdoor rated 
junction boxes (not supplied) away from areas 
where they may be at risk from being cut, trapped or 
damaged.

•  This is a floodlight product, and therefore should be 

positioned where it will not cause a glare hazard.

•  We recommend that you use H05RN-F specification 

cable (not supplied) which is an outdoor grade, 
rubber sheathed cable. The mains supply cable must 
have a minimum cross sectional area of 1.0mm² 
Cables must be protected using suitable conduit or 

plastic trunking.

•  Avoid mounting on surfaces subject to vibration, as 

this may affect the PIR sensor.

•  To avoid damage to the unit, do not aim the sensor 

towards the sun or areas of strong electro-magnetic 
disturbances.

•  To avoid nuisance triggering, the sensor should be 

aimed away from heat sources, such as BBQ’s, 
Air-Conditioners, other outside lighting, moving cars 
and flue vents or reflective surfaces such as smooth 
white walls or swimming pools.

•  When selecting location, it is advisable to note that 

movement across the sensors field is more effective 
than towards/away from it.

Existing fittings must be completely removed before 
installation of a new product. Before removing the 
existing fitting, carefully note the position of each set 
of wires
.

•  Decide on the optimum location for the product. 

•  Remove the fixing bracket from the product by 

removing the bolts and spring washers. Keep safe 
for refitting later.

•  Hold the bracket in position and mark the location 

of the fixing holes. A minimum of two fixing points 
must be used.

•  Drill and plug the wall at the marked positions.

•  Fix the bracket to the wall using the screws and 

plugs. Ensure the wall is capable of holding the 
weight of the product. Take care to avoid damaging 
any concealed wiring and pipes. The correct fixings 

should be used for brick or cavity walls.

•  Undo screws holding the Junction Box Cover and 

remove.

•  Loosen Gland to allow cable to pass through. Feed 

cable through, allowing enough length to connect to 
terminal block.

•  Wire as detailed below.

•  Re-fit Junction Box Cover, ensuring excess cable 

slack is pulled through, and seal is correctly seated..

•  Fit product to wall bracket, ensuring bolts are 

tightened fully.

•  Refit product to bracket ensuring spring washers 

are fitted onto the bolts and that the bolts are fully 
tightened.

Installation

Connect the supply cable to the terminals as indicated 
below. The only terminals that will need to be connected 

are the supply live, supply neutral and supply earth 
terminals.

Wiring

Check that...

•  You have correctly identified the wires.
•  The connections are tight.

•  No loose strands have been left out of the connection 

block.

Internal 
earth

Supply
neutral
(N - Blue)

Supply
earth
(Yellow/
Green)

Supply
live
(L - Brown)

Sensor

neutral

Sensor 
Return
live

Sensor 
Supply
live

LED -

LED +