Using Aroma Oils
Sweat Fittings
When using sweat fittings use only tin base solder with a melting point below 315
ºC
.
Do not overheat. Ends of water supply tubing must be thoroughly cleansed for a minimum
distance of 25mm from ends. Do not remove valve cover.
To Check Operation
1. Turn on SAWO and allow tank to fill with water.
2. Turn off SAWO control. Water should stay in tank.
3. Turn off power at the panel box. Water should discharge from tank.
4. Turn on power at panel box.
5. Repeat.
PROVIDE DRAIN PLUMBING ACCORDING TO LOCAL REQUIREMENTS.
PLUMB AS REQUIRED FOR GRAVITY DRAIN SYSTEM.
Aroma oil
10ml bottle with
integrated
dropper
Recess for
essential oil
Steam head
(install per instructions
on page 5)
Steam emission slot
Optional Automatic Drain System
12
!
CAUTION
!
CAUTION
!
CAUTION
Enjoy aroma oils by placing a drop or
two into your steamhead as shown in
the attached illutration. Only use SAWO
aroma oils in a SAWO steamhead, or any
other equivalent oil deemed suitable for
use in the SAWO steamhead.
Use aroma oils with caution.
aroma oils are for external use only. Keep
out of reach of children. aroma oils are highly
concentrated and are potent substances and
should not be applied directly to the skin as they
can be irritants. Use aroma oils with caution.
Place the drops into the SAWO steamhead recess prior to turning on the
steambath. Do not place drops in a hot steamhead as SERIOUS INJURY CAN RESULT IF YOU
DO NOT FOLLOW THIS WARNING.
Start with one drop to gauge strength and suitability. Limit to a maximum of a few
drops during a steambathing session. Some people may find that the aroma makes dizzy and
the user should exit the steam bath IMMEDIATELY. If skin irritation occurs stop using the oils
immediately. Remove any excess oil by washing in mild soap and water. If ingested, rinse
mouth with water. Administer water or milk to dilute. contact a physician immediately.
13
Select Your SAWO Model
1. Measure the Length, Width, and Height (in meters)
of steam shower or tub/shower being used.
Multiply the Length x Width x Height to get
the basic room volume in m
(a)
L x W x H =
2. Add 15% of (a) for each of the following design features
that describe the steambath enclosure:
b. Each exterior wall, or uninsulated attic, or crawlspace
above or below ceiling or floor
.
c. Tile on mud wall
d. An extra glass panel in addition to the door
e. A cast iron tub or marble bench
f. Each foot exceeding 2.5 meters height
3. If the interior wall construction material within the steam
enclosure is natural marble, stone, shale, glass block or
concrete, copy the figure from box (a) to box (g).
Add Boxes (b) through (g) to box (a) = Total Cubic Meter
required.
a + b + c + d + f + g =
L
W
H
a
b
c
d
e
f
g
h
Compare the total m³ required (h) to the specification chart below and select the appropriate model.
_______________________________________________________________________________________________________
IMPORTANT:
The formula for selecting the steambath generator is a recommendation only.
Because of variables in construction, these sizing instructions and specifications should be
considered as guidelines only. SAWO will review the model selected provided we receive complete
information, including working drawings, specifications, and pertinent electrical and construction
details. Otherwise the manufacturer disclaims responsibility for the sizing of a model selected.
3
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
Model No.
Kw
Maximum Room
Volume (m³)
_____________________________________________________________________
STR45-1
4.5
2
STR45-3
4.5
2
STR60-1
6.0
5
STR60-3
6.0
5
STR75-1
7.5
7
STR75-3
7.5
7
STR90-1
9.0
11
STR90-3
9.0
11
STR120-3
12.0
16
STR150-3
15.0
19
SELECTION CHART