assembly and Installation
1. Location of the steam generator has to be near the steam room. Place it within 7.5
meters to the steam room.
2. Steam generator has to be installed outside the steam room.
3. The steam generator must not be installed outdoors or areas that may damage the
unit due to climate conditions.
4. Do not install the steam generator or plumbing lines in unheated attic or any locations
where water could freeze.
5.
The steam generator must not be installed in areas near flammable or corrosive
materials or chemicals such as gasoline, paint thinners, chlorine or the like.
6. Provide a level surface to install steam generator. Side hole slots are provided for wall
mounting. Make sure that the steam generator is secured and is level when mounted
on the wall.
7. The steam generator has to be installed in an upright position only.
8.
Install water filter and softener or alike when necessary.
9. Leave enough space for service and maintenance of the generator.
Plumbing
The plumbing has to be done by a qualified licensed plumber. Plumbing should be in
accordance with national or local codes. Use unions for piping connections. Use only
prescribed brass piping or copper tubing. Never use black or galvanized pipe for the
plumbing as it can easily crack or damage.
Minimum space for service and Maintenance
Wall Installation
For illustrative purposes only.