ENGLISH
9
Min 5
Min 20
Min 5
A
20
1200
1900
150
5
B
300
288
275
C
33
5
31
0
335
300
288
275
Wall Mounting Rack Installation
A
B
C
NRMN-23Ni2
NRMN-30Ni2
NRMN-36Ni2
50
50
50
30
30
30
85
85
85
Kuva 2
Fig. 2
Löylynohjaimen asentaminen
How to install Reflector
HEATER INSTALLATION
The heater gets very hot. To avoid the risk of accidental contact with the heater, it is
recommended that a heater guard be provided.
The cable used for sauna wiring must be HO7RN-F type or its equivalent. A certified
electrician must do the installation of the heater to ensure safety and reliability. Improper
electrical connection can cause electric shock or fire. Refer to the electrical diagram (See
Taivuta pihdeillä ja
aseta aukkoon.
Bend using pliers.
Insert to the hole
Taivuta 90°
Bend 90° to lock.
HUOM!
Heijastinpelti tulee asentaa
paloriskin minimoimiseksi.
NOTE!
Reflector must be installed
to prevent risk of fire.
It is recommended that the heater be placed on the wall nearest to the door. The air
circulation created by the door should work together with the hot air generated by the
heater. For safety and convenience, follow the minimum safety distances as provided (See
Fig 1.). Follow the cubic volumes (See page 38). Do not install the heater to the floor
or wall niche. Install only one heater in a sauna room.
Be sure to build a strong foundation for the mounting rack (e.g. cross struts in sauna
paneling) or reinforce the wall with a thick board to prevent the heater from collapsing.
Attach the heater to the wall with the aid of the mounting rack. Screws (6 pieces) are
provided for fastening of the rack to the wall. To affix the heater to the rack, lift the heater
and fit the nuts that are placed at the back of the heater to the slots on both sides at the
top of the rack. Lock at least one of the side screws to prevent the heater from being
accidentally moved.