0 =
=
=
II
I
OFF
LIGHT ON
UNIT ON
0
II
I
Sauna Type
Domestic sauna
Hotels, Condominiums
Public sauna
DIP switch
1,2,3
1h
Sauna on-time
Heater on-time
Session time
2h
4h
001
010
011
000
100
101
110
111
6h
8h
12h
18h
24h
5h 15min-
sauna
5h 45min-
sauna
Max. time
Max. pre-run time
99h
*) IEC 60335-2-53
MAXIMUM SESSION TIME
The maximum sauna session time depends on the purpose of the sauna. For domestic use,
the total on-time of the sauna is limited to 6 hours. It includes pre-run time and the session
time*. The factory setting for the control unit is 6 hours.
For condominiums, hotels and similar locations, the operating period of the sauna heater is
limited to 12 hours, including the session time.
For public sauna, the operating period of the sauna heater can be either 18 or 24 hours. Please
note, if the public sauna is set to 24 hours, it will be on constantly. It needs to be continuously
attended.
The maximum heater on-time is set by the switches on DIP switch in the power controller, (See
also DIP switch session time settings in page 21). Only a qualified electrician can change the
settings. The standards and regulations of the country where the control unit is installed must
be followed when setting the DIP switch. Default time is 6 hours. See table below.
THE HEATER MAIN SWITCH
The heater main switch can be found on the lower part
of the heater. Using this switch, you can isolate the
electronics from the mains power supply.
In order to put the unit into operation, switch to the first
position (switch position I). In this switch position all
control unit’s functions work normally.
In case of breakdown, press the control unit switch on
the left part of the rocker to the middle position (switch
position 0). The unit is now completely switched off.
In order to switch on the light in the sauna when the
unit is switched off, press on the left part of the rocker
to the second position (switch position II). Quality
requirements for water which is thrown to the heater.