【Check 6】 Compressor Rated Current. (Fig.6)
◇Checking point
Test result
Judge
Approx. 1.5 - 2.0A
Normal
Lower than 1.5A
Gas is leaking.
【Check 7】 Resistance of Thermistor. (Fig.7)
◇Checking point
If want to check the start-up of the fan motor directly,
can check by connecting the DC24V directly. (Fig.7)
6. CHECK POINT
&
CHECK METHOD
Current value measurement with clamp meter between
input cord terminals.
Higher than 2.0A
Compressor is locked, or
contaminated.
15
Fig.7
・Please be careful not to mistake the polarity
of the power supply.
・When connect with DC24V or wrong polarity,
fan motor will fail.
・Please use such as support coupler so as
not to short-circuit power.
Fig.6
To measure the rated current of the compressor,
please measure after 15 minutes or more after
starting the refrigerator.
WORK TIPS