10
Problem
Fan will not start.
Fan sounds
noisy.
Lights shut off
and will not
come back on.
Solution
1.Check circuit fuses or breakers.
2. Check line wire connections to the fan and switch wire connections
in the switch housing.
CAUTION: Make sure main power is off.
1. Make sure all motor housing screws are snug.
2. Make sure the screws that attach the fan blade bracket to the motor
hub is tight.
3. Make sure wire nut connections are not rubbing against each other
or the interior wall of the switch housing.
CAUTION: Make sure main power is off.
4. Allow a 24-hour "breaking-in" period. Most noise associated with a
new fan disappear during this time.
5. If using an optional light kit, make sure the screws securing the
glassware are tight. Check that light bulb is also secure.
6. Some fan motors are sensitive to signals from solid-state variable
speed controls. If you have installed this type of control, choose and
install another type of control.
7. Make sure the upper canopy is a short distance from the ceiling. It
should not touch the ceiling.
1. This unit is equipped with a wattage limiting device. Lamping in
excess of 190 watts will disable your ceiling fan's light kit. To reset your
light kit you must turn the power off and re lamp, keeping the
wattage under 190 watts. Restore power to your ceiling fan and
continue normal operation.
15. TROUBLESHOOTING