background image

Placing the Tag for Best Performance

9

 Typical locations include mounting the tag inside the middle of the 
container or on the outside of the container on a flat surface.

For best performance, make sure the tag is:

Mounted on a metal surface.

Mounted at no less than a 6 foot (1.8m) elevation.

Mounted vertically.

Not mounted behind or between metal objects

The next figure shows an example of a tag mounted on an ISO container 
according to the performance guidelines.

Figure 3:

Asset tag mounted on an ISO container door

Note:  

Make sure you clean the surface of the container or other asset 

before attaching the tag.

The tag will have 400-foot (122m) read/write range to Savi SR-650 Fixed 
Readers. For the most consistent communications with the tag, the Fixed 
Readers must be mounted:

to have an unobstructed line-of-sight to the tag

Summary of Contents for ST-618

Page 1: ...Installation Guide Savi ST 618 Asset Tag...

Page 2: ...rdance with the terms of the agreement It is against the law to copy the software on any medium except as specifically allowed in the license or nondisclosure agreement THIS DOCUMENTATION CONTAINS CON...

Page 3: ...Contents 1 ST 618 Asset Tag Description 5 Features 6 Activating the Tag 6 Placing the Tag for Best Performance 8 Mounting the Tag 10 Replacing the Battery 12 Contacting Savi Support 13 Specifications...

Page 4: ...4...

Page 5: ...ing and managing medium to high value assets in both defense and commercial applications The ST 618 carries enough memory to record asset configuration and maintenance records and is ideal for these f...

Page 6: ...ttery with typical life of five years FCC HERO ETSI RoHS Directive 2002 95 EC certified Activating the Tag The tag is shipped in sleep mode You must remove and re insert the battery to wake up the tag...

Page 7: ...the tag will emit 5 beeps Then the tag will emit 2 short beeps to indicate adequate battery voltage or 3 short beeps if a fresh battery is required Whenever a battery is inserted into a tag the tag a...

Page 8: ...50 80 F or 10 27 C Placing the Tag for Best Performance Savi Technology recommends that you mount the tag on a flat surface with the tag aligned vertically For best performance place the tag as high...

Page 9: ...mounted behind or between metal objects The next figure shows an example of a tag mounted on an ISO container according to the performance guidelines Figure 3 Asset tag mounted on an ISO container do...

Page 10: ...ort The fastener you choose often depends on the material from which the asset or container is constructed and your personal preference There are two accessory mounting packages which are sold separat...

Page 11: ...fastened to an asset you can leave it on the asset even after the tag is removed so it is available for future use with other compatible tags Prior to re use visually inspect the PST mounted sleeve t...

Page 12: ...rocedures for safely disposing of lithium batteries The battery cannot be reused or recharged 3 Install a 3 6V lithium A battery matching the negative and posi tive terminals to the symbols shown on t...

Page 13: ...annot find the information you need contact Savi Support Services Check http supportcenter savi com for contact information Send an email to help savi com Call 1 888 994 SAVI North America only or 1 6...

Page 14: ...ion Environmental Temperature 32 C to 70 C operating 40 C to 85 C storage Humidity 95 non condensing Vibration and shock MIL STD 810F Weatherproofing IP64 Manufacturing RoHS Directive 2002 95 EC Wirel...

Page 15: ...extend battery life Diagnostics Reports low tag battery status when battery is too low to support 500 UHF reads Digital Database memory Onboard non volatile user accessible memory 2 KB Accessories Mou...

Page 16: ...Savi ST 618 Asset Tag Installation Guide 16...

Reviews: