11
4. Input Function Parameters
Set during running available
Parameter
Parameter functions
Setting range
Factory
setting
4-09
Speed tracking after external
alarm reset
0:Tracking downwards from speed before
external alarm
1:Tracking upwards from min speed
0
5. Multi-step Speed and Auto-Program Operation Parameters
Set during running available
Parameter
Parameter functions
Setting range
Factory
setting
5-00
Multi frequency 1
0.0 to 400Hz
0.0
5-01
Multi frequency 2
0.0 to 400Hz
0.0
5-02
Multi frequency 3
0.0 to 400Hz
0.0
5-03
Multi frequency 4
0.0 to 400Hz
0.0
5-04
Multi frequency 5
0.0 to 400Hz
0.0
5-05
Multi frequency 6
0.0 to 400Hz
0.0
5-06
Multi frequency 7
0.0 to 400Hz
0.0
5-07
Multi frequency 8
0.0 to 400Hz
0.0
5-08
Multi frequency 9
0.0 to 400Hz
0.0
5-09
Multi frequency 10
0.0 to 400Hz
0.0
5-10
Multi frequency 11
0.0 to 400Hz
0.0
5-11
Multi frequency 12
0.0 to 400Hz
0.0
5-12
Multi frequency 13
0.0 to 400Hz
0.0
5-13
Multi frequency 14
0.0 to 400Hz
0.0
5-14
Multi frequency 15
0.0 to 400Hz
0.0
5-15
Pattern Operation(Mode)
0. Pattern operation inactive
1. Active (Stop after operating for 1 cycle)
2. Active (Pattern operation performs in cycles
until STOP command input)
3. Active (Stop after operating for 1 cycle) (with
STOP intervals).
4. Active (Pattern operation performs in cycles
until STOP command input) (with STOP
intervals).
0
5~16
(Rotating Operation) (0 to 7
th
step speed)
0 to 255( 0: Forward Run 1: Reverse Run)
0
5-17
(Rotating Operation) (8 to 15
th
step speed)
0 to 255( 0: Forward Run 1: Reverse Run)
0
5-18
(Step 0 Time)
0 to 65500S
0
5-19
(Step 1 Time)
0 to 65500S
0
5-20
(Step 2 Time)
0 to 65500S
0
5-21
(Step 3 Time)
0 to 65500S
0
5-22
(Step 4 Time)
0 to 65500S
0
5-23
(Step 5 Time)
0 to 65500S
0
5-24
(Step 6 Time)
0 to 65500S
0
5-25
(Step 7 Time)
0 to 65500S
0
5-26
(Step 8 Time)
0 to 65500S
0
5-27
(Step 9 Time)
0 to 65500S
0