10
Vuelift Mini Owner’s Manual
81375-A-OM-EN
Drive train
Type: Winding drum
Motor: 1.77 HP (1.32 kW) @ 60 Hz with integrated brake
Motor control: Preprogrammed variable frequency
drive
Distance between
landings
93 in (2362 mm) minimum
Pit depth
Minimum: 3 in (76 mm); 4 in (102 mm) with buffer
springs (required if habitable space below)
Maximum: 12 in (305 mm)
Temperature operating
range
–10 °C to +40 °C (14 °F to 104 °F)
NOTE: For optimal running conditions, each landing of
the unit should be in a climate-controlled
environment.
Max. noise level
At no time does the noise level of the lift exceed 70 db
during operation.
Safety features
Pit run/stop switch and car top run/stop switch
Emergency stop switch
Safety brakes
Overspeed
Manual lowering
Emergency battery back-up for cab lighting and
lowering
Options
Optional configurations: Type 2 cab
Optional colors:
• White (Texture White PX521W859)
• Silver (Texture Silver PX521S343)
• Custom powder-coat frame
Note that Black is the standard color (Texture Black
PX622N365)
Savaria Link remote monitoring
Pitless option with ramp
Sabbath service
Flood switch
Buffer springs for habitable space below
Buck boost transformer
Up to 6 stops; balcony attachment or thru-floor
configuration
Cab shipped disassembled
Landing door handle painted to match unit
Top header ring in sheet metal painted to match unit