18
V1504 Owner’s Manual
Part No. 000692, 30-m06-2017
Operator Troubleshooting
The following table lists potential problems and their possible solutions.
If the problem persists, contact your Authorized Dealer.
Potential Problem
Possible Solution
Platform goes up but does not
come down
Check the underpan sensor. Pull down on the
underpan to ensure the pan is not stuck in the
activated position.
Platform comes down but does
not go up
Check the power supply (breaker, cord, battery,
etc.).
Platform does not move
Check that the key is ON (if applicable).
Check that the doors are closed.
Check to see if the Emergency Stop is pushed in;
it should be pulled out for normal operation.
If the platform is at the top landing, check the
underpan sensor as described above.