15
Part No. 001081, 28-m08-2018
Telecab17 Owner’s Manual
Operator Troubleshooting
The following table lists potential problems and their possible solutions.
If the problem persists, contact your Authorized Dealer.
Potential Problem
Possible Solution
Telecab17 goes up but does not
come down.
Check the underpan sensors. Pull down on the
underpan to ensure the pan is not stuck in the
activated position.
Telecab17 comes down but
does not go up.
Check the power supply (breaker, cord, battery,
etc.).
Check the floor plug switches. Lift the floor plug
to ensure it is not stuck in the activated position.
Telecab17 does not move.
Check that the key turned to the on position.
Check that the door is closed.
Check to see if the Emergency Stop is pushed in;
it should be pulled out for normal operation.
If the Telecab17 is at the bottom landing, check
the floor plug switches as described above.
If the Telecab17 is at the top landing, check the
underpan sensor as described above.