5. MAINTENANCE

The owner can perform the 2-month inspections, but the 6-month 
inspections 

must

 be performed by a Qualified Technician. Contact your 

Authorized Dealer

.

Units installed in adverse environments will require additional 
maintenance on a monthly basis.

IMPORTANT:

 Please test the phone in your elevator during every maintenance. 

If the phone is inactive, please shut down the elevator until the phone line is 
active. This applies to all lifts in a hoistway or enclosure models

Maintenance Schedule

Verification by owner

Frequency

Verify general operation of the Telecab17

Every 2 months

Verify operation of the safety devices:

• Underpan sensors (safety switches)
• Floor plug sensors (safety switches)
• Door  contact
• Door  lock
• Emergency  stop

Every 2 months

Verification by technician

Frequency

Verify operation of the emergency lowering system

Every 6 months

Verify operation of the safety brake

Every 6 months

Check the safety components:

• Chains
• Chain connecting links
• Chain pulleys and shafts
• Parts holding the chains on the roller supports
• Chain tensioners on the rail (ensure they are tight)
• Cylinder head (cotter pins, cracks, welds)
• Hydraulic system (check for leaks)
• Fastening devices (check for looseness)
• Up relays – verify that one of the two up relays is not stuck 

in the activated position. Use a multimeter to verify that 
every normally-open contact is open when the relays are 
not being activated.

Every 6 months

Check the rollers (function and wear)

Every 6 months

Check for oil leaks

Every 6 months

NOTE

Summary of Contents for Telecab17

Page 1: ...OWNER S MANUAL To Be Retained by Owner After Installation by Authorized Savaria Dealer Part No 001081 28 m08 2018 Telecab17 Residential Elevator ...

Page 2: ... more frequently where usage environment or local jurisdiction requires As the Owner you are responsible for ensuring that regular service and inspections occur in a timely manner Refer to this manual for specifications operating instructions and maintenance of the Telecab17 Residential Elevator Upon completion of installation the dealer must provide you with the following information and ensure i...

Page 3: ...t pay careful attention to the important notes below Read this manual carefully before using the equipment To prevent accidents adhere strictly to the instructions and keep clear of moving parts at all times Follow instructions on all equipment labels at all times Replace any damaged labels immediately Ensurethat only qualified personnelperform maintenance and service on the unit When replacing pa...

Page 4: ... Owner s Manual Part No 001081 28 m08 2018 1 DESCRIPTION Figure 1 shows the components of the Telecab17 Figure 1 Door lock Emergency phone Handrail Non skid platform Door handle Car operating panel COP Door latch ...

Page 5: ...direction and 24 VDC down direction Levels serviced 2 levels Platform Non skid platform Power supply circuit supplied by others 110 VAC 30A 60 Hz single phase Lighting supply circuit supplied by others 120 volt 15A 60 Hz single phase Motor pump 24 VDC 3 Hp 2 1 kW Gear type hydraulic pump Electrical Automatic battery recharging system 115 VAC Low voltage controls Drive system 2 1 roller chain hydra...

Page 6: ...etector built into the cab Door interlock Hydraulic door closer Underpan safety sensor Emergency stop and alarm Emergency battery lowering Manual emergency lowering Fully enclosed drive tower Pressure relief valve to prevent platform overload Slack chain safety device Two halogen lights in cab Telephone in cab Optional equipment Battery operation in up and down directions ...

Page 7: ... object underneath it The Telecab17 will stop moving in the up direction if it reaches the floor plug and the floor plug sensor detects an object on it that weighs more than 20 lb 9 1 kg 4 When the cab reaches the landing the door will unlock automatically 5 Exit the cab and close the door 6 To prevent unauthorized use of the lift take the key out when the unit is not in operation 7 Pressing the E...

Page 8: ... the desired direction Note the following The Telecab17 will not move if the door is open The Telecab17 will stop moving in the down direction if the underpan sensor detects an object underneath it The Telecab17 will stop moving in the up direction if it reaches the floor plug and the floor plug sensor detects an object on it that weighs more than 20 lb 9 1 kg 3 When the cab reaches the landing th...

Page 9: ...the cab door locked when the Telecab17 is operating or not at a landing The door open sensor prevents the Telecab17 from moving when the cab door is open Emergency Door Opening The cab door can be opened using the emergencykeyprovided notethattwo identical emergency keys are provided To open the door in an emergency situation insert the key into the hole of the WR 500 lock Figure 5 and turn it Not...

Page 10: ...sing the red Emergency Stop button during travelwill stop theelevator immediately and activate the alarm The Emergency Stop overrides the landing stations hall calls Pull the Emergency Stop out to return the elevator to normal operation Alarm Button Pressing the Alarm button during travel will activate the alarm If the door is locked at a landing you can press the Alarm button to unlock the curren...

Page 11: ... Telecab17 Pull on the steel cable located inside the manual lowering box to lower the Telecab17 to the bottom level For units with a 12V DC pump there is a key switch located on the side of the Telecab17 Insert the same key used for call send control into the key switch and turn it to the operating position The cab will descend to the bottom level This mechanism is for emergency use only After us...

Page 12: ...evices Underpan sensors safety switches Floor plug sensors safety switches Door contact Door lock Emergency stop Every 2 months Verification by technician Frequency Verify operation of the emergency lowering system Every 6 months Verify operation of the safety brake Every 6 months Check the safety components Chains Chain connecting links Chain pulleys and shafts Parts holding the chains on the rol...

Page 13: ...7 Owner s Manual Check the hydraulic fluid level Every 6 months Check the battery fluid level optional system Also check the voltage with the charger unplugged 13 VDC unloaded and no lower than 10 11 VDC when running up down Every 6 months ...

Page 14: ...14 Telecab17 Owner s Manual Part No 001081 28 m08 2018 Maintenance Record Date Time Reason for Call Comments Dealer ...

Page 15: ...e activated position Telecab17 comes down but does not go up Check the power supply breaker cord battery etc Check the floor plug switches Lift the floor plug to ensure it is not stuck in the activated position Telecab17 does not move Check that the key turned to the on position Check that the door is closed Check to see if the Emergency Stop is pushed in it should be pulled out for normal operati...

Page 16: ...Inc 2 Walker Drive Brampton Ontario L6T 5E1 Canada www savaria com For service or questions about this product please contact your installing dealer DEALER NAME _________________________________________________ DEALER PHONE _________________________________________________ Authorized Savaria Dealer ...

Reviews: