13

Part No. 001103, 28-m08-2018

M2LIFT Owner’s Manual

Maintenance Record

Date

Time

Reason for Call

Comments

Dealer

Summary of Contents for 001103

Page 1: ...OWNER S MANUAL To Be Retained by Owner After Installation by Authorized Savaria Dealer Part No 001103 28 m08 2018 M2LIFT Vertical Platform Lift ...

Page 2: ...ore frequently where usage environment or local jurisdiction requires As the Owner you are responsible for ensuring that regular service and inspections occur in a timely manner Refer to this manual for specifications operating instructions and maintenance of the M2LIFT Upon completion of installation the dealer must provide you with the following information and ensure it is recorded in this manu...

Page 3: ...ATIONS 6 3 OPERATION 7 Attendant Operation 7 Operating from the COP Controls 7 Operating from the Landing Station Controls 8 4 ADDITIONAL FEATURES 9 Safety Underpan 9 Gate Lock 10 Safety Brake 10 Emergency Stop Button 10 Battery Lowering 10 5 MAINTENANCE 11 Maintenance Schedule 12 Maintenance Record 13 Operator Troubleshooting 14 ...

Page 4: ...uipment labels at all times Replace any damaged labels immediately Ensurethat only qualified personnelperform maintenance and service on the unit When replacing parts be sure that only genuine Savaria parts are used This unit is intended for use by a mature person who understands its proper operation as set out in this manual Prior to operation make sure that All doors and gates are locked and sec...

Page 5: ... Figure 1 shows the exterior components of the M2LIFT Figure 1 Tower Car operating Landing gate panel COP Opposite Safety underpan Access ramp Motor cover Base support legs Non skid platform Fascia panel Tower rail cap COP side wall side wall Landing sill Pit switch ...

Page 6: ...wer supply 120 VAC 15A 60 Hz single phase Drive system Direct drive gear Chain suspension Motor 24 VDC 1 3 HP geared Controller LUT125 PCB Finish Electrostatic powder coat paint on all metallic surfaces and vacuumed formed plastics Standard features 24VDC operation Wireless call send stations at landings Constant pressure type buttons Operating control buttons on platform Automatic battery recharg...

Page 7: ... Operating from the COP Controls Figure 2 shows the car operating panel COP Figure 2 To operate the lift from the COP controls 1 Insert the key into the key switch and turn it to the ON position to activate the operating buttons 2 Apply constant pressure on the Up Down button as required to move the platform to the desired landing Note that the lift will not move if the gate is open 3 When the lif...

Page 8: ...es of landing stations hall calls Figure 3 To operate the lift from the landing call send station controls 1 Insert the key into the key switch and turn it to the ON position to activate the operating buttons 2 Press the appropriate landing button to move the platform to the desired landing Note that the lift will not move if the gate is open 3 When the lift reaches the landing the door will unloc...

Page 9: ...RES Safety Underpan The safety underpan shown in Figure 4 is located under the platform The underpan has sensors that detect any obstacles and stop the downward travel of the lift This is optional on enclosed units and required on open hoistways Figure 4 Safety Underpan ...

Page 10: ...he gate open and then turn the key a half turn counter clockwise to remove it from the lock DO NOT open the gate if there is any chance of falling from the platform Safety Brake The motor Safety Brake stops the platform in the event of a chain failure During normal operation the chain tension keeps the brake mechanism up so the brake cam does not interfere with the tower guide rail If a chain fail...

Page 11: ...onsmust be performed by a Qualified Technician Contact your Authorized Dealer to schedule maintenance Notethatunitsinstalledinadverseenvironmentswillrequireadditional maintenance on a monthly basis Figure 6 Technicians must always use the shoring pin when working under the lift see below for pin location NOTE DANGER Hole for shoring pin ...

Page 12: ...n of the lift Operation of the underpan sensors Operation of the emergency stop Operation of the gate lock contacts The lift should not run unless the gate is closed and locked Every 6 months Check the suspension system Chains Connecting links Chain pulleys and shafts Parts holding the chains on the roller supports Chain tensioners on the rail they should be tight Every 6 months Verify that all ha...

Page 13: ...13 Part No 001103 28 m08 2018 M2LIFT Owner s Manual Maintenance Record Date Time Reason for Call Comments Dealer ...

Page 14: ...pan sensors Pull down on the underpan to ensure the pan is not stuck in the activated position Platform comes down but does not go up Check that the power cord is plugged in Platform does not move Check that the key is ON Check that the gate is closed Check to see if the Emergency Stop buttons on the COP and tower are pushed in they must be pulled out for normal operation If the platform is at the...

Page 15: ......

Page 16: ... Drive Brampton Ontario L6T 5E1 Canada www savaria com For service or questions about this product please contact your installing dealer DEALER NAME _________________________________________________ DEALER PHONE _________________________________________________ Authorized Savaria Dealer ...