3.3.8 MANIFOLD PRESSURE REGULATOR ADJUSTMENT
The manifold pressure regulator controls gas input and flame height, and is pre-adjusted at the
factory. No further adjustment is required.
PILOT FLAME ADJUSTMENT
For proper operation, the pilot and main burner flames must be steady and not lifting off or floating. The
top 3/8” – 1/2” (10-13mm) of the thermocouple should be
engulfed by the pilot flame.
3.3.9 PRIMARY AIR ADJUSTMENT / AJUSTEMENT DE L'AIR PRIMAIRE
Aeration is factory set but may need adjustment for altitude or movement during shipping. / L'aération est
réglée en usine, mais peut nécessiter un ajustement de l'altitude ou le mouvement pendant le transport.
To adjust the air shutter / Pour ajuster l'obturateur d'air
1/. Turn off the gas / Fermez le gaz
2/. Remove the door / Enlevez la porte
3/. Remove glass or logs from burner / Retirer le verre ou des billes de brûleur
4/. Remove the burner pan / Retirer la casserole du brûleur
5/. Undo the set screw on the air shutter and adjust accordingly then retighten the set screw. / Défaire la
vis de réglage sur le volet d'air et d'ajuster en conséquence, puis resserrez la vis de
réglage.
6/. Reassemble the fireplace in reverse order from 4 through 2. / Remonter la cheminée dans l'ordre
inverse de 4 à 2.
7/. Turn on the gas. / Allumez le gaz.
Air tube and Air shutter shown removed
for clarity purposes only.
Set Screw