background image

12 

 

FH-BA-e-2020 

Storage of peak values and average value calculation 

 

(from up to 10 measured values) 
 
Storage of the peak values in the measuring instrument 
 

  Activation of the "AUTO PEAK function" via the PEAK button  

 

  Deactivation of the "Average Function" via the MEMORY key 

 

  Now all peak values are automatically transferred to the instrument memory.  

 

 

Individual peak values can be recalled using the arrow keys ▲ and ▼ (displayed 
in the upper display segment) 

 

  The average value can be called up via the MEMORY button (visible in the upper 

display segment)  

 

  Deleting the memo

ry contents by pressing ▼ button in AVERAGE mode 

 

 

Assignment of the RS 232 data interface 

SUB-D 9Pin male 

 

Pin 

Signal 

Designation 

TxD 

Data output 

RxD 

Input for control 

signal 

GND 

Ground 

+1.6 to + 2 V 

> upper limit value 

+1.6 to + 2 V 

< lower limit value 

+1.6 to + 2 V 

OK 

 

 

Summary of Contents for FH 10

Page 1: ...GmbH Ziegelei 1 D 72336 Balingen e mail info kern sohn com Phone 49 0 7433 9933 0 Fax 49 0 7433 9933 149 Internet www sauter eu Instruction manual digital force gauge SAUTER FH Version 2 0 01 2020 GB PROFESSIONAL MEASURING ...

Page 2: ...ny questions requests or suggestions Table of contents Introduction 3 Scope of delivery 3 Technical data 4 3 1 Technical data FH with internal loadcell up to 500N 4 3 2 Technical data FH with external load cell up to 500N 5 3 3 Technical data FH with external load cell from 1kN 6 3 4 Technical data external load cell from 1kN 7 Battery operation power supply 8 Display indication 8 Control buttons ...

Page 3: ...using other parts or even the gauge itself have not been damaged If any damage is evident please notify SAUTER GmbH immediately Sensor outside ext stands for a measuring cell outside the housing SAUTER offers optional software and accessories to make the measuring instrument more versatile in use Please ask SAUTER or the SAUTER supplier or visit our website www sauter eu Scope of delivery SAUTER F...

Page 4: ...nternal loadcell up to 500N Measuring device FH 10 FH 20 FH 50 FH 100 FH 200 FH 500 Capacity 10N 20N 50N 100N 200N 500N Work temperature 10 C to 30 C Relative air humidity 15 to 80 Humidity Weight Approx 640g Dimensions Display unit LxWxH 240x65x35mm Thread M6 ...

Page 5: ...ext FH 20 ext FH 50 ext FH 100 ext FH 200 ext FH 500 ext Capacity 10N 20N 50N 100N 200N 500N Measurement uncertainty 0 5 of Max measuring range Work temperature 10 C to 30 C Relative air humidity 15 to 80 Humidity Weight display unit Approx 600g Dimensions display unit LxWxH 240x65x35mm Thread M6 ...

Page 6: ...scription of how to attach all force measuring devices to SAUTER test benches is given in the operating instructions of the respective test benches Measuring device FH 1k FH 2k FH 5k FH 10k FH 20k FH 50k FH 100k capacity 1000N 2000N 5000N 10000N 20000N 50000N 100000N Measurement uncertainty 0 5 of Max measuring range Working temperature 10 C to 30 C Relative air humidity 15 to 80 Humidity Weight d...

Page 7: ...ell from 1kN Maximum load LxWxH Thread type Cable length 1 kN 76x51x19mm M12x1 75 Approx 2 5m 2 kN 76x51x19mm M12x1 75 5 kN 76x51x28mm M12x1 75 10 kN 76x51x28mm M12x1 75 20 kN 76x51x28mm M12x1 75 50 kN 108x76x25 5mm M18x1 5 100 kN 178x125x51mm M30x2 0 ...

Page 8: ...ted to the mains via the charging cable the integrated battery is charged Battery operating time approx 15h Display indication Position Description 1 Measurement result 2 Display unit of the measurement result 3 Activating the print function 4 battery charge indicator 5 PEAK indicates that peak hold mode is activated AUTO PEAK holds the peak value in the display for a defined time only 6 Average v...

Page 9: ...arm Display 1x Press Lower limit value LodT To change or see section Limit value display 1x Press Lower limit value to activate the memory function for peak value measurements Peak LE SET Lo Pe see also section Minimum Limit Function To change or Only activated in Peak Mode see section Limit Value Display 1 Press once Auto Stop function to switch off the test bench when a limit force is reached Se...

Page 10: ...e or Backlight PEAK peak value Assignment with three functions Track mode continuous measurement Peak mode peak value acquisition Auto Peak mode like Peak function but without minimum limit function MEMORY memory function Saves the peak value for calculating the average of the measurement results see section Saving the peak values Delete function Erasing memory values only in Memory mode PRINT pri...

Page 11: ...under Buttons Simple measurement track mode Display pos 1 of the currently acting force and force direction pos 7 arrow Zero position through Peak Hold Function Peak Mode Switch over by pressing Auto Peak Hold Mode Auto Peak Mode Switch over by pressing Minimum limit value function to activate the measured value storage This function is used for measurements where unwanted pre peaks occur that are...

Page 12: ...ferred to the instrument memory Individual peak values can be recalled using the arrow keys and displayed in the upper display segment The average value can be called up via the MEMORY button visible in the upper display segment Deleting the memory contents by pressing button in AVERAGE mode Assignment of the RS 232 data interface SUB D 9Pin male Pin Signal Designation 2 TxD Data output 3 RxD Inpu...

Page 13: ...ing or 1021 15 means 21 15 N tractive force Warnings Incorrectly performed force measurements can lead to serious injury to persons and damage to objects and must therefore only be performed by trained and experienced personnel In particular it must be avoided that forces act on the purchased measuring instrument that exceed the maximum load Max of the instrument or that do not act axially on the ...

Page 14: ...people do not use it as an infant measuring instrument The measuring device does not comply with the German Medical Devices Act MPG Never operate the measuring instrument in rooms where there is a risk of explosion The standard version is not explosion proof The design of the measuring instrument must not be changed This can lead to incorrect measurement results safety related defects and the dest...

Page 15: ...rpose as well as the type and scope of this inspection Information on the monitoring of measuring instruments and the necessary test weights is available on the SAUTER homepage www sauter eu The weights and measuring instruments can be checked and adjusted quickly and at favourable prices in KERN s accredited DAkkS laboratory traceability to the national standard Note To view the CE declaration pl...

Page 16: ...In the meantime if you are back in normal mode turn off the power and start over from step 1 If necessary press keys faster 4 select device Use the keys to select the maximum load N of the respective device The value matching the device is shown in the display 5 save settings Press SET 6 switch to calibration Press MEMORY The right red light comes on 7 indicate the available calibration weight Pre...

Page 17: ...FH BA e 2020 17 Technical drawings Connection of the Charger Reset button LCD display Lamp for limit value display RS 232 4 pole plug Control buttons reset button Specifications in mm Reset button ...

Reviews: